An optical sensor for the sensitive determination of formaldehyde gas based on chromotropic acid and 4-aminoazobenzene immobilized in a hydrophilic membrane

Formaldehyde is a common contaminant in occupational and environmental atmospheres, prolonged exposure leads to health risks, and its determination is necessary to protect health. There is a great demand for portable, rapid, and sensitive methods that can be used in resource-limited settings. In thi...

Full description

Saved in:
Bibliographic Details
Published in:Analyst (London) Vol. 148; no. 18; p. 4533
Main Authors: Fernández-Ramos, M D, Moraga-Cabezas, A, Medina-Castillo, Antonio L, Capitán-Vallvey, L F
Format: Journal Article
Language:English
Published: England 11-09-2023
Subjects:
Online Access:Get more information
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Formaldehyde is a common contaminant in occupational and environmental atmospheres, prolonged exposure leads to health risks, and its determination is necessary to protect health. There is a great demand for portable, rapid, and sensitive methods that can be used in resource-limited settings. In this respect, a colorimetric sensor has been developed based on the colour change from pink to purple of co-immobilized chromotropic acid and 4-aminoazobenzene in hydroxypropyl methylcellulose when it is exposed to different concentrations of formaldehyde. The concentration of formaldehyde in the gas phase was quantified by measuring the change of the appropriate colour coordinates in response to the concentration of formaldehyde. A calibration curve was obtained for formaldehyde, with a useful concentration range from 0.08 to 0.6 ppmv. The detection limit was 0.016 ppmv, which is lower than the maximum exposure concentrations recommended by both the World Health Organization (WHO) and the Occupational Safety and Health Administration (OSHA). The optical sensor was found to have good reproducibility, with a relative standard deviation of 2.3 and 1.7% at 0.08 and 0.25 ppmv, respectively. The sensor can operate at room temperature and environmental humidity, 25 °C, and 50% RH, respectively. In addition, a study of interferents (acetaldehyde, toluene, methanol, ethyl acetate, acetone, acetic acid, carbon dioxide and ammonia) showed high selectivity for formaldehyde, which indicates that this membrane is a simple, fast, and economical alternative for quantifying the concentration of formaldehyde in different environments.
ISSN:1364-5528
DOI:10.1039/d3an01056b