Dialysis grafts arterial plug : Retrieval using the tulip sheath device in vitro

The "arterial plug" is a resistant thrombus that frequently persists at the arterial anastomosis of clotted hemodialysis grafts following thrombolytic therapy. We studied the physical and morphological characteristics of the plug and determined the feasibility of transcatheter removal in v...

Full description

Saved in:
Bibliographic Details
Published in:Cardiovascular and interventional radiology Vol. 20; no. 2; pp. 154 - 158
Main Authors: SHARAFUDDIN, M. J, TITUS, J. L, GU, X, HUNTER, D. W, AMPLATZ, K
Format: Journal Article
Language:English
Published: Heidelberg Springer 01-03-1997
Berlin Springer Nature B.V
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The "arterial plug" is a resistant thrombus that frequently persists at the arterial anastomosis of clotted hemodialysis grafts following thrombolytic therapy. We studied the physical and morphological characteristics of the plug and determined the feasibility of transcatheter removal in vitro using the tulip compression thrombectomy system. Sixteen thrombus plugs were recovered during surgical thrombectomy of clotted human dialysis grafts. The physical and gross physical characteristics of all plugs were analyzed. Eight specimens were evaluated microscopically. Transcatheter compression thrombectomy of eight plugs was attempted in vitro. Each plug was embedded in a polyvinyl tube filled with newly clotted blood and connected to a flow circuit. First, balloon-assisted aspiration thrombectomy (BAT) of soft thrombus was performed, while sparing the distal-most segment containing the plug. The tulip sheath was then introduced facing the "arterial end" of the tube. The thrombus segment containing the plug was pulled back into the tulip mesh using either a 3 Fr Fogarty balloon catheter or a self-expanding rake. The tulip was closed to compress and remove the trapped plug. Near-complete thrombectomy of soft clot was achieved in all tested tubes. Compression and retrieval of the entire arterial plug was successful in all except one, where only partial compression of the plug occurred, presumably due to fibrotic changes. No fragmentation or embolization occurred in the remaining procedures. Spongy consistency was noted in 94% of the specimens. Microscopic evaluation showed organized layered thrombus with compaction in five plugs. Transcatheter removal of a thrombus plug is feasible in vitro using the tulip compression-thrombectomy system.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0174-1551
1432-086X
DOI:10.1007/s002709900126