A novel procedure of secondary voice prosthesis insertion from the inside out: The modified Fukuhara method
To present a new procedure for inserting a secondary voice prosthesis from the inside to the outside, which improves on the method previously reported by Fukuhara et al. A flexible nasopharyngoscope was used to puncture pharynx (or transplanted jejunum) from the inside to the outside. In this method...
Saved in:
Published in: | Auris, nasus, larynx Vol. 49; no. 4; pp. 658 - 662 |
---|---|
Main Authors: | , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Netherlands
Elsevier B.V
01-08-2022
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | To present a new procedure for inserting a secondary voice prosthesis from the inside to the outside, which improves on the method previously reported by Fukuhara et al.
A flexible nasopharyngoscope was used to puncture pharynx (or transplanted jejunum) from the inside to the outside. In this method, it was possible to use the PROVOX® VegaTM Puncture Set as it is used for the placement of the voice prosthesis.
We were able to place the PROVOX® VegaTM in all cases we experienced. Most of the cases had a history of radiation therapy. The time required for surgery ranged from 11–59 minutes (mean: 29 minutes) and there was no measurable amount of bleeding.
This new method using the PROVOX® VegaTM Puncture Set, which is designed for the original purpose of voice prosthesis implantation, was therefore found to be safe and effective. |
---|---|