Comparison of orofacial thermal sensitivity assessed with simple devices and sophisticated equipment

Background Simple thermal devices providing reliable data are needed to detect somatosensory disturbances in non‐specialized clinical settings. Currently, evidence is lacking about their use. Therefore, the aim was to compare the assessment of perceived thermal sensitivity/pain in healthy humans wit...

Full description

Saved in:
Bibliographic Details
Published in:European journal of pain Vol. 22; no. 10; pp. 1824 - 1832
Main Authors: Ayranci, M., Koutris, M., Lobbezoo, F., Svensson, P., Baad‐Hansen, L.
Format: Journal Article
Language:English
Published: England 01-11-2018
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background Simple thermal devices providing reliable data are needed to detect somatosensory disturbances in non‐specialized clinical settings. Currently, evidence is lacking about their use. Therefore, the aim was to compare the assessment of perceived thermal sensitivity/pain in healthy humans with a state‐of‐the‐art thermotester and with simple inexpensive customized thermal aluminium devices. Methods Twenty healthy volunteers participated in the study. The infraorbital region and the tip of the tongue were tested with the Medoc Pathway thermotester and simple aluminium thermal devices, with temperatures varying between 5–50°C. A numerical rating scale (NRS) from 0–50–100 was used for rating the perceived thermal sensitivity/painfulness. A control experiment was performed with 10 of the participants to test the potential impact of temporal summation of thermal stimuli with the use of temperature ramps (Medoc) compared with static temperature (simple devices). Results In the original experiment, the scores from the thermotester stimulation were higher than the scores for stimulation with the simple thermal devices with mean NRS differences between devices of 7.2 and 10.2 for the two tested regions. In the control experiment, the mean NRS differences decreased to −0.3 and 2.2, respectively. Conclusions Provided that temporal summation of the thermal stimuli was avoided, there were only minor differences in perceived thermal sensitivity/painfulness between the two different assessment methods at both test sites. Therefore, the simple thermal devices can be useful for assessment of thermal sensitivity in clinical settings without access to expensive sophisticated equipment. However, more sophisticated equipment is needed for threshold measurements. Significance This study indicates that simple thermal devices to some extent can be used in a comparable way with sophisticated thermal stimulators. Therefore, they can be useful in clinical practice, where access to further equipment is lacking.
Bibliography:Conflicts of interest
Funding sources
This study was financially supported by the Foundation for Dental Science, Denmark.
None declared.
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-News-1
ObjectType-Feature-3
content type line 23
ISSN:1090-3801
1532-2149
1532-2149
DOI:10.1002/ejp.1278