Laboratory validation of a diffusive sampler for the determination of glutaraldehyde in air
A diffusive sampling method has been validated for determination of glutaraldehyde in air. The sampler consists of a filter impregnated with 2,4-dinitrophenylhydrazine, mounted in a polypropylene housing. The uptake rate was determined to be 11.8 ml/min, with a relative standard deviation of 13%. Th...
Saved in:
Published in: | Journal of Chromatography A Vol. 710; no. 1; pp. 175 - 180 |
---|---|
Main Authors: | , |
Format: | Journal Article |
Language: | English |
Published: |
Elsevier B.V
25-08-1995
|
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A diffusive sampling method has been validated for determination of glutaraldehyde in air. The sampler consists of a filter impregnated with 2,4-dinitrophenylhydrazine, mounted in a polypropylene housing. The uptake rate was determined to be 11.8 ml/min, with a relative standard deviation of 13%. The effect of glutaraldehyde concentration, sampling time and relative humidity on uptake rate was undetectable or small. The temperature effect was significant, about 1.5%/°C. The samplers are stable for at least two weeks at 22°C. The detection limit is about 0.03 mg/m
3 for a 15-min sample. |
---|---|
ISSN: | 0021-9673 |