Lumen-apposing metal stents for benign gastrointestinal tract strictures: An international multicenter experience

AIM To investigate technical feasibility, outcomes and adverse events of the lumen-apposing metal stent(LAMS) for benign gastrointestinal(GI) tract strictures.METHODS Between July 2015 and January 2017, patients undergoing treatment by LAMS for benign GI strictures at three tertiary referral centers...

Full description

Saved in:
Bibliographic Details
Published in:World journal of gastrointestinal endoscopy Vol. 9; no. 12; pp. 571 - 578
Main Authors: Santos-Fernandez, Javier, Paiji, Christopher, Shakhatreh, Mohammad, Becerro-Gonzalez, Irene, Sanchez-Ocana, Ramon, Yeaton, Paul, Samarasena, Jason, Perez-Miranda, Manuel
Format: Journal Article
Language:English
Published: United States Baishideng Publishing Group Inc 16-12-2017
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:AIM To investigate technical feasibility, outcomes and adverse events of the lumen-apposing metal stent(LAMS) for benign gastrointestinal(GI) tract strictures.METHODS Between July 2015 and January 2017, patients undergoing treatment by LAMS for benign GI strictures at three tertiary referral centers were included in this study. Primary outcomes included technical success, shortterm clinical success, long-term clinical success, and adverse events. Short-term clinical success was defined as symptom resolution at 30 d after stent placement. Longterm clinical success was defined by symptom resolution at 60 d in patients who continued to have indwelling stent, or continued symptom resolution at 30 d after elective stent removal.RESULTS A total of 21 patients(mean age 62.6 years, 47.6% males) underwent placement of LAMS for benign GI strictures. A 15 mm × 10 mm LAMS was placed in 16 patients, a 10 mm × 10 mm LAMS was placed in 2 patients, and a 16 mm × 30 mm LAMS was placed in 3 patients. Technical success was obtained in all cases. Short-term clinical success was achieved in 19 out of 21 cases(90.5%), and long-term clinical success was achieved in 12 out of 18(66.7%). Mean(range) stent indwell time was 107.2(28-370) d. After a mean(range) dwell time of 104.3(28-306) d, 9 LAMSs were removed due to the following complications: ulceration at stent site(n = 1), angulation(n = 2), migration(n = 4) and stricture overgrowth(n = 2). Migration occurred in 4 cases(19.0%), and it was associated with stricture resolution in one case. Median(range) follow-up period was 119(31-422) d. CONCLUSION Utilization of LAMS for benign strictures has shown to be technically feasible and safe, but adverse events highlight the need for further study of its indications.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Correspondence to: Manuel Perez-Miranda, MD, PhD, Gastroenterology Department, Hospital Universitario Rio Hortega, Calle Antonio Lorenzo Hurtado 2, Valladolid 47012, Spain. mperezmiranda@saludcastillayleon.es
Author contributions: Santos-Fernandez J, Shakhatreh M, Yeaton P, Samarasena J and Perez-Miranda M contributed to study conception and design; Santos-Fernandez J, Paiji C, Shakhatreh M, Becerro-Gonzalez I, Sanchez-Ocana R, Yeaton P, Samarasena J and Perez-Miranda M contributed to data acquisition, data analysis and interpretation, and writing of article; Santos-Fernandez J, Paiji C, Shakhatreh M, Samarasena J and Perez-Miranda M contributed to editing, reviewing and final approval of article.
Telephone: +34-98-3420400-85701
ISSN:1948-5190
1948-5190
DOI:10.4253/wjge.v9.i12.571