Development of overuse tendinopathy: A new descriptive model for the initiation of tendon damage during cyclic loading

ABSTRACT Tendinopathic tissue has long been characterized by changes to collagen microstructure. However, initial tendon damage from excessive mechanical loading—a hallmark of tendinopathy development—could occur at the nanoscale level of collagen fibrils. Indeed, it is on this scale that tenocytes...

Full description

Saved in:
Bibliographic Details
Published in:Journal of orthopaedic research Vol. 36; no. 1; pp. 467 - 476
Main Authors: Herod, Tyler W., Veres, Samuel P.
Format: Journal Article
Language:English
Published: United States 01-01-2018
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:ABSTRACT Tendinopathic tissue has long been characterized by changes to collagen microstructure. However, initial tendon damage from excessive mechanical loading—a hallmark of tendinopathy development—could occur at the nanoscale level of collagen fibrils. Indeed, it is on this scale that tenocytes interact directly with tendon matrix, and excessive collagen fibril damage not visible at the microscale could trigger a degenerative cascade. In this study, we explored whether initiation of tendon damage during cyclic loading occurs via a longitudinal compression‐induced buckling mechanism of collagen fibrils leading to nanoscale kinkband development. Two groups of tendons were cyclically loaded to equivalent peak stresses. In each loading cycle, tendons in one group were unloaded to the zero displacement mark, while those in the other group were unloaded to a nominal level of tension, minimizing the potential for fibril buckling. Tendons that were unloaded to the zero displacement mark ruptured significantly sooner during cyclic loading (1,446 ± 737 vs. 4,069 ± 1,129 cycles), indicating that significant fatigue damage is accrued in the low stress, toe region of the load‐deformation response. Ultrastructural analysis using scanning electron microscopy of tendons stopped after 1,000 cycles showed that maintaining a nominal tension slowed the accumulation of kinkbands, supporting a longitudinal compression‐induced buckling mechanism as the basis for kinkband development. Based on our results, we present a new descriptive model for the initiation of tendon damage during cyclic loading. The so‐called Compression of Unrecovered Elongation or CUE Model may provide useful insight into the development of tendinopathy. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:467–476, 2018.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0736-0266
1554-527X
DOI:10.1002/jor.23629