Double Salts Iodide Scintillators: Cesium Barium Iodide, Cesium Calcium Iodide, and Barium Bromine Iodide

In this study we review the state‐of‐the‐art for double salt iodide scintillators, in particular cesium barium iodide (CBI), cesium calcium iodide (CCI) and barium bromine iodide (BBI), as well as report on their scintillation and optical properties. Double salt iodides inherently have high density...

Full description

Saved in:
Bibliographic Details
Published in:Crystal research and technology (1979) Vol. 48; no. 4; pp. 227 - 235
Main Authors: Rowe, E., Tupitsyn, E., Wiggins, B., Bhattacharya, P., Matei, L., Groza, M., Buliga, V., Burger, A., Beck, P., Cherepy, N.J., Payne, S.A.
Format: Journal Article
Language:English
Published: Berlin WILEY-VCH Verlag 01-04-2013
WILEY‐VCH Verlag
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In this study we review the state‐of‐the‐art for double salt iodide scintillators, in particular cesium barium iodide (CBI), cesium calcium iodide (CCI) and barium bromine iodide (BBI), as well as report on their scintillation and optical properties. Double salt iodides inherently have high density and atomic number which translates to good stopping power for energetic particles, in particular gamma rays. Light yields of 54,000 ph/MeV for CBI, 51,000 ph/MeV for CCI, and 46,000 ph/MeV for BBI were measured. A FWHM energy resolution for the 662 keV full absorption peak was observed at 5.7% for CBI, 16.3% for CCI and 3.56% for BBI. The principal scintillation decay timing for CBI was 840 ns, 462 ns for BBI, and two distinct time components of 9 ns and 1900 ns were observed for CCI. In this study we review the state‐of‐the‐art for double salt iodide scintillators, in particular cesium barium iodide (CBI), cesium calcium iodide (CCI) and barium bromine iodide (BBI), as well as report on their scintillation and optical properties. Double salt iodides inherently have high density and atomic number which translates to good stopping power for energetic particles, in particular gamma rays. Light yields of 54,000 ph/MeV for CBI, 51,000 ph/MeV for CCI, and 46,000 ph/MeV for BBI were measured. A FWHM energy resolution for the 662 keV full absorption peak was observed at 5.7% for CBI, 16.3% for CCI and 3.56% for BBI. The principal scintillation decay timing for CBI was 840 ns, 462 ns for BBI, and two distinct time components of 9 ns and 1900 ns were observed for CCI.
Bibliography:ArticleID:CRAT201300010
istex:04CFADFB55E0E3DB7EE7275CEC0C77E793E9E601
ark:/67375/WNG-H9R1W8JL-W
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:0232-1300
1521-4079
DOI:10.1002/crat.201300010