Assessment of microwave-assisted enzymatic digestion by measuring glycated hemoglobin A1c by mass spectrometry
Enzymatic digestion of proteins and analysis of the resulting peptides by mass spectrometry is an established approach in proteomics and in clinical and environmental chemistry. The long digestion times of several hours prevent the fast turnover of samples and results. Qualitative applications showe...
Saved in:
Published in: | Rapid communications in mass spectrometry Vol. 19; no. 19; pp. 2865 - 2870 |
---|---|
Main Authors: | , , , |
Format: | Journal Article |
Language: | English |
Published: |
Chichester, UK
John Wiley & Sons, Ltd
01-01-2005
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Enzymatic digestion of proteins and analysis of the resulting peptides by mass spectrometry is an established approach in proteomics and in clinical and environmental chemistry. The long digestion times of several hours prevent the fast turnover of samples and results. Qualitative applications showed that microwave radiation profoundly shortens enzymatic digestion. However, its usefulness for quantitative applications had not been assessed. In this study, the microwave‐assisted enzymatic digestion of hemoglobin at different temperatures, buffer concentrations, and digestion times was assessed and compared with conventional digestion for the proteolytic enzymes trypsin and Glu‐C. A microwave‐assisted enzymatic digestion method optimized for digestion time and temperature was applied for the analysis of glycated hemoglobin HbA1c and compared with a reference method. Using trypsin, complete digestion was obtained at 50°C within 20 min. Under these conditions, the digestion efficiency was 20% higher than with conventional trypsin digestion. These effects were not observed with Glu‐C as enzyme, probably because of the decreased stability of Glu‐C at elevated temperatures in comparison with the trypsin used. The comparison of the optimized microwave‐assisted digestion method using trypsin with the reference method for HbA1c using Glu‐C gave a close correlation in the results (R2: 0.996). A significant bias of 0.33% HbA1c was observed, with higher values obtained with the microwave‐assisted tryptic digest; this finding might have resulted from the use of a different enzyme. This study showed that microwave‐assisted enzymatic digestion can substantially reduce digestion times to minutes and can be used in qualitative as well as quantitative applications. Published in 2005 by John Wiley & Sons, Ltd. |
---|---|
Bibliography: | ArticleID:RCM2135 istex:BA594C8384EA25E115E58F8C5A0413C8000E9FC0 Use of trade and company names is for identification only and does not imply endorsement by the Centers for Disease Control and Prevention, the Agency for Toxic Substances and Disease Registry, the Public Health Service and the U.S. Department of Health and Human Services. ark:/67375/WNG-C03MM5N7-T ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 0951-4198 1097-0231 |
DOI: | 10.1002/rcm.2135 |