Anatomical Variations of the Epitympanum and the Usable Space for Middle Ear Implants Analyzed With CT-assisted Imaging Using a Tablet-based Software

To evaluate interindividual anatomical variations of the epitympanum and the usable space for implantation of active middle ear implants (AMEI) as well as the usefulness of a tablet-based software to assess individual anatomy on computed tomography (CT) scans. CT scans of 126 patients, scheduled for...

Full description

Saved in:
Bibliographic Details
Published in:Otology & neurotology Vol. 43; no. 4; pp. e454 - e460
Main Authors: Grueninger, Ivo, Lippl, Lisa, Canis, Martin, Simon, Florian, Spiro, Judith E., Spiegel, Jennifer L., Hempel, John Martin, Müller, Joachim, Volgger, Veronika
Format: Journal Article
Language:English
Published: United States Lippincott Williams & Wilkins 01-04-2022
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To evaluate interindividual anatomical variations of the epitympanum and the usable space for implantation of active middle ear implants (AMEI) as well as the usefulness of a tablet-based software to assess individual anatomy on computed tomography (CT) scans. CT scans of 126 patients, scheduled for cochlea implantation (50.8% men; 0.6-90.0 yr) without middle ear malformations or previous middle ear surgery and with slice thickness ≤0.7 mm were analyzed. Since no standardized measurements to assess the size of the epitympanum are available, relevant distances were defined according to anatomical landmarks. Three independent raters measured these distances using a tablet-based software. Interrater correlation was computed to evaluate the quality of the measurement process. Descriptive data were analyzed for validation and for evaluation of interindividual anatomical variations. Influence of age and sex on the taken measurements was assessed. No relevant correlation between age or sex and the anatomy of the epitympanum was found. Interrater correlation ranged from Spearman's ρ = 0.3-0.9 and there were significant differences between individual rater results for various combinations. Descriptive data revealed high interindividual anatomical variance of the epitympanum, especially regarding the distance between incus and skull base. The reported descriptive data regarding the anatomy of the epitympanum emphasizes the importance of preoperative planning, especially since the height of the epitympanum showed great interindividual variance potentially limiting implantation of AMEIs. The herein used tablet-based software seems to be convenient for preoperative assessment of individual anatomy in the hand of otosurgeons.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1531-7129
1537-4505
DOI:10.1097/MAO.0000000000003486