Effect of shaped filter design on dose and image quality in breast CT

The purpose of this study was to investigate the effect of shaped filters specifically designed for dedicated breast computed tomography (CT) scanners on dose and image quality. Optimization of filter shape and material in fan direction was performed using two different design methods, one aiming at...

Full description

Saved in:
Bibliographic Details
Published in:Physics in medicine & biology Vol. 58; no. 12; p. 4205
Main Authors: Lück, Ferdinand, Kolditz, Daniel, Hupfer, Martin, Kalender, Willi A
Format: Journal Article
Language:English
Published: England 21-06-2013
Subjects:
Online Access:Get more information
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract The purpose of this study was to investigate the effect of shaped filters specifically designed for dedicated breast computed tomography (CT) scanners on dose and image quality. Optimization of filter shape and material in fan direction was performed using two different design methods, one aiming at homogeneous noise distributions in the CT images and the other aiming at a uniform dose distribution in the breast. The optimal filter thickness as a function of fan angle was determined iteratively to fulfil the above mentioned criteria for each breast diameter. Different filter materials (aluminium, copper, carbon, polytetrafluoroethylene) and breast phantoms with diameters between 80-180 mm were investigated. Noise uniformity in the reconstructed images, obtained from CT simulations based on ray-tracing methods, and dose in the breast, calculated with a Monte Carlo software tool, were used as figure of merit. Furthermore, CT-value homogeneity, the distribution of noise in cone direction, spatial resolution from centre to periphery and the contrast-to-noise ratio weighted by dose (CNRD) were evaluated. In addition, the decrease of scatter due to shaped filters was investigated. Since only few or one filter are practical in clinical CT systems, the effects of one shaped filter for different breast diameters were also investigated. In this case the filter, designed for the largest breast diameter, was simulated at variable source-to-filter distances depending on breast diameter. With the filter design method aiming at uniform noise distribution best results were obtained for aluminium as the filter material. Noise uniformity improved from 20} down to 5} and dose was reduced by about 30-40} for all breast diameters. No decrease of noise uniformity in cone direction, CT-value homogeneity, spatial resolution and the CNRD was detected with the shaped filter. However, a small improvement of CNRD was observed. Furthermore, a scatter reduction of about 20-30} and a more homogeneous scatter distribution were reached which led to reduced cupping artefacts. The simulations with one shaped filter at variable source-to-filter distance resulted in nearly homogeneous noise distributions and comparable dose reduction for all breast diameters. In conclusion, by means of shaped filters designed for breast CT, significant dose reduction can be achieved at unimpaired image quality. One shaped filter designed for the largest breast diameter used with variable source-to-filter distance appears to be the best solution for breast CT.
AbstractList The purpose of this study was to investigate the effect of shaped filters specifically designed for dedicated breast computed tomography (CT) scanners on dose and image quality. Optimization of filter shape and material in fan direction was performed using two different design methods, one aiming at homogeneous noise distributions in the CT images and the other aiming at a uniform dose distribution in the breast. The optimal filter thickness as a function of fan angle was determined iteratively to fulfil the above mentioned criteria for each breast diameter. Different filter materials (aluminium, copper, carbon, polytetrafluoroethylene) and breast phantoms with diameters between 80-180 mm were investigated. Noise uniformity in the reconstructed images, obtained from CT simulations based on ray-tracing methods, and dose in the breast, calculated with a Monte Carlo software tool, were used as figure of merit. Furthermore, CT-value homogeneity, the distribution of noise in cone direction, spatial resolution from centre to periphery and the contrast-to-noise ratio weighted by dose (CNRD) were evaluated. In addition, the decrease of scatter due to shaped filters was investigated. Since only few or one filter are practical in clinical CT systems, the effects of one shaped filter for different breast diameters were also investigated. In this case the filter, designed for the largest breast diameter, was simulated at variable source-to-filter distances depending on breast diameter. With the filter design method aiming at uniform noise distribution best results were obtained for aluminium as the filter material. Noise uniformity improved from 20} down to 5} and dose was reduced by about 30-40} for all breast diameters. No decrease of noise uniformity in cone direction, CT-value homogeneity, spatial resolution and the CNRD was detected with the shaped filter. However, a small improvement of CNRD was observed. Furthermore, a scatter reduction of about 20-30} and a more homogeneous scatter distribution were reached which led to reduced cupping artefacts. The simulations with one shaped filter at variable source-to-filter distance resulted in nearly homogeneous noise distributions and comparable dose reduction for all breast diameters. In conclusion, by means of shaped filters designed for breast CT, significant dose reduction can be achieved at unimpaired image quality. One shaped filter designed for the largest breast diameter used with variable source-to-filter distance appears to be the best solution for breast CT.
Author Kolditz, Daniel
Kalender, Willi A
Lück, Ferdinand
Hupfer, Martin
Author_xml – sequence: 1
  givenname: Ferdinand
  surname: Lück
  fullname: Lück, Ferdinand
  email: ferdinand.lueck@imp.uni-erlangen.de
  organization: Institute of Medical Physics, Friedrich-Alexander-University Erlangen-Nürnberg, 91052 Erlangen, Germany. ferdinand.lueck@imp.uni-erlangen.de
– sequence: 2
  givenname: Daniel
  surname: Kolditz
  fullname: Kolditz, Daniel
– sequence: 3
  givenname: Martin
  surname: Hupfer
  fullname: Hupfer, Martin
– sequence: 4
  givenname: Willi A
  surname: Kalender
  fullname: Kalender, Willi A
BackLink https://www.ncbi.nlm.nih.gov/pubmed/23715466$$D View this record in MEDLINE/PubMed
BookMark eNo1j0tOwzAUAC0Eoh-4AUK-QMjz316iKBSkSmzKunqO7RKUJiFOF709lYDV7EYzK3LdD30k5IHBEwNrSwDBCseUKpUtGS8lB3VFlkxoVmilYUFWOX8BMGa5vCULLgxTUuslqeuUYjPTIdH8iWMMNLXdHCcaYm4PPR16GoYcKfaBtkc8RPp9wq6dz7TtqZ8i5plWuztyk7DL8f6Pa_LxUu-q12L7vnmrnrdFI6SdCwMowHKfHAbjlHROGxmYQOMcOLSN9yik8igFA2cVBs5RXapjsNh4w9fk8dc7nvwxhv04XZqm8_7_h_8As3pL2A
CitedBy_id crossref_primary_10_1002_mp_12247
crossref_primary_10_1038_s41598_020_77923_0
crossref_primary_10_1364_OE_24_022749
crossref_primary_10_1088_1361_6560_ac5fe1
crossref_primary_10_1002_mp_15374
crossref_primary_10_1088_2057_1976_abb834
crossref_primary_10_1117_1_JMI_1_3_033505
crossref_primary_10_1117_1_JMI_5_1_015502
crossref_primary_10_1002_mp_14026
crossref_primary_10_1088_0031_9155_59_19_5691
crossref_primary_10_1080_21681163_2020_1852601
crossref_primary_10_3233_XST_17263
ContentType Journal Article
DBID CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1088/0031-9155/58/12/4205
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList MEDLINE
Database_xml – sequence: 1
  dbid: ECM
  name: MEDLINE
  url: https://search.ebscohost.com/login.aspx?direct=true&db=cmedm&site=ehost-live
  sourceTypes: Index Database
DeliveryMethod no_fulltext_linktorsrc
Discipline Medicine
Biology
Physics
EISSN 1361-6560
ExternalDocumentID 23715466
Genre Research Support, Non-U.S. Gov't
Journal Article
GroupedDBID ---
-DZ
-~X
123
1JI
4.4
5B3
5RE
5VS
5ZH
7.M
7.Q
9BW
AAGCD
AAJIO
AAJKP
AALHV
AATNI
ABCXL
ABHWH
ABJNI
ABLJU
ABQJV
ABVAM
ACAFW
ACGFS
ACHIP
AEFHF
AENEX
AERVB
AFYNE
AKPSB
ALMA_UNASSIGNED_HOLDINGS
AOAED
ASPBG
ATQHT
AVWKF
AZFZN
CBCFC
CEBXE
CGR
CJUJL
CRLBU
CS3
CUY
CVF
DU5
EBS
ECM
EDWGO
EIF
EJD
EMSAF
EPQRW
EQZZN
F5P
HAK
IHE
IJHAN
IOP
IZVLO
JCGBZ
KOT
LAP
M45
N5L
N9A
NPM
NT-
NT.
P2P
PJBAE
R4D
RIN
RNS
RO9
ROL
RPA
S3P
SY9
TN5
UCJ
W28
XPP
ID FETCH-LOGICAL-c348t-70a3082bf9ad795499674d13a79909a8cbba345ba4310985ad22a5011ed8acb72
IngestDate Sat Sep 28 08:09:09 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 12
Language English
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-c348t-70a3082bf9ad795499674d13a79909a8cbba345ba4310985ad22a5011ed8acb72
PMID 23715466
ParticipantIDs pubmed_primary_23715466
PublicationCentury 2000
PublicationDate 2013-06-21
PublicationDateYYYYMMDD 2013-06-21
PublicationDate_xml – month: 06
  year: 2013
  text: 2013-06-21
  day: 21
PublicationDecade 2010
PublicationPlace England
PublicationPlace_xml – name: England
PublicationTitle Physics in medicine & biology
PublicationTitleAlternate Phys Med Biol
PublicationYear 2013
SSID ssj0011824
Score 2.2175736
Snippet The purpose of this study was to investigate the effect of shaped filters specifically designed for dedicated breast computed tomography (CT) scanners on dose...
SourceID pubmed
SourceType Index Database
StartPage 4205
SubjectTerms Equipment Design
Humans
Image Processing, Computer-Assisted
Mammography - instrumentation
Phantoms, Imaging
Quality Control
Radiation Dosage
Scattering, Radiation
Signal-To-Noise Ratio
Title Effect of shaped filter design on dose and image quality in breast CT
URI https://www.ncbi.nlm.nih.gov/pubmed/23715466
Volume 58
hasFullText
inHoldings 1
isFullTextHit
isPrint
link http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9QwELZ2qUC9IFoehULlAzcUNn6kdo4QtuqlvXSRuFV-JGKlNrtSy4F_z4zHya4WgcqBS5SMlSjy92Uy9rwYe-9L50ptSljk1LBAcTLAN-dN4aSAC6WwlSpuXVyZy2_2y1zPJ5OhaclG9l-RBhlgjZmz_4D2-FAQwDlgDkdAHY4Pwj2XIwYb8O67W4M52S1vqA04hmqgbyBiiHryGdxiwA6lVab0P48R6vcfmsW2yZpiREMKmx0c8YkvuXzTGNGDLvfPDWnXsxZ411NzkJxZcxOXqXVsTmrf0GndEWuooMF4A_y4-kgjaU8ob7rmDYrULKKgrOePLSlVdSoKLPKzrXUru80uuaVDtUyJ2L8rd1CIKRpSiQKr2sN5hQKBJWR3bwJQ1rcJYqkMmInU2uXvozuFt4ehKZuCGYWWdnMxOqhgWaaHTExrZ-NLzSo7E3KGr4N1pvMjdtYsyXZZPGNP86KDfyK2HLBJ2x-yx9SG9Oche3KRcQVhRvs5mxOR-KrjRCROROJEJL7qORKJA8g8EYlnIvFlz4lIvFm8YF_P5ovmvMg9N4qgtL0vTOmwgJHvahcNuoDrU6OjUM6A2VI7G7x3SlfeaSwpaysXpXQVzEcbrQveyJfsUb_q2yPGy4guWm9ELbxWofRBeF8G1YIwyE6-Zq9oUq7XVFjlepiuN38cOWb7G4q9ZXsdfLXtOza9iz9OEkC_AL5dWd4
link.rule.ids 782
linkProvider EBSCOhost
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Effect+of+shaped+filter+design+on+dose+and+image+quality+in+breast+CT&rft.jtitle=Physics+in+medicine+%26+biology&rft.au=L%C3%BCck%2C+Ferdinand&rft.au=Kolditz%2C+Daniel&rft.au=Hupfer%2C+Martin&rft.au=Kalender%2C+Willi+A&rft.date=2013-06-21&rft.eissn=1361-6560&rft.volume=58&rft.issue=12&rft.spage=4205&rft_id=info:doi/10.1088%2F0031-9155%2F58%2F12%2F4205&rft_id=info%3Apmid%2F23715466&rft_id=info%3Apmid%2F23715466&rft.externalDocID=23715466