Simultaneous analysis of 23 priority volatile compounds in water by solid-phase microextraction-gas chromatography-mass spectrometry and estimation of the method's uncertainty

Most water contaminations with volatile organic compounds (VOCs) are traceable to leaking underground fuel reservoirs, solvent storage vessels, agricultural practices, industrial residues, and deficient wastewater treatment and disposal. In order to perform effective monitoring of such organic micro...

Full description

Saved in:
Bibliographic Details
Published in:International journal of environmental analytical chemistry Vol. 88; no. 3; pp. 151 - 164
Main Authors: Guimarães, Ana Dias, Carvalho, José JoÃo, GonÇalves, Carlos, Alpendurada, Maria de Fátima
Format: Journal Article
Language:English
Published: Taylor & Francis Group 15-03-2008
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Most water contaminations with volatile organic compounds (VOCs) are traceable to leaking underground fuel reservoirs, solvent storage vessels, agricultural practices, industrial residues, and deficient wastewater treatment and disposal. In order to perform effective monitoring of such organic micropollutants in a straightforward manner, a multiresidue method for the determination of 23 VOCs (trihalomethanes (THMs), BTEX and chlorinated solvents) in water has been developed using solid-phase microextraction (SPME) and capillary gas chromatography-mass spectrometry (GC-MS). This group includes also methyl-tert-butyl ether, epichlorhydrine, and vinyl chloride which present additional analytical difficulties. Three different fibres were assayed: 7-µm polydimethylsiloxane (PDMS), 100-µm PDMS, and 75-µm Carboxen-PDMS, and the extraction conditions were optimized. The best results for the majority of the analytes and mainly for those with the lowest signals were obtained using the Carboxen-PDMS fibre after 15 min of extraction in the headspace mode at a room temperature of 20 ± 2°C. The analytical sensitivity, linearity, precision, accuracy, and uncertainties have been studied for method validation in agreement with the international standard ISO/IEC 17025:2005. The limits of detection achieved with the proposed method (0.06-0.17 µg L −1 ) are adequate to determine the VOCs at the restrictive levels established by the European legislation. This was a decisive achievement to enable the analysis of all VOCs listed under the drinking-water directive in a single assay. The method exhibits performance capabilities suitable for routine analysis of VOCs in drinking-water by quality-control laboratories as enforced by EU Directives. The method is currently being used for this purpose, and participation in proficiency tests was assessed, with encouraging results.
ISSN:0306-7319
1029-0397
DOI:10.1080/03067310701642982