Feedback Linearization Control in Photovoltaic Module Integrated Converters
The strive to increase the energy yield of photovoltaic (PV) power systems has made PV module integrated dc-dc converters (dc-MICs) a reality of modern PV plants. These converters regulate their input voltage, and their dynamic behavior is heavily influenced by the non-linear characteristic of the P...
Saved in:
Published in: | IEEE transactions on power electronics Vol. 34; no. 7; pp. 6876 - 6889 |
---|---|
Main Authors: | , , , |
Format: | Journal Article |
Language: | English |
Published: |
New York
IEEE
01-07-2019
The Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The strive to increase the energy yield of photovoltaic (PV) power systems has made PV module integrated dc-dc converters (dc-MICs) a reality of modern PV plants. These converters regulate their input voltage, and their dynamic behavior is heavily influenced by the non-linear characteristic of the PV module. The regulation of the PV module voltage and average inductor current by means of a linear cascaded controller is a popular control technique, simplifying the converter dynamics, and providing inherent current limiting; however, it is prone to instability depending on the interaction between the PV source and the interfacing converter, as well as the value of the controller parameters. These factors present a clear challenge for control design; moreover, the converter transient response undesirably depends on the PV module operating point. In order to solve these issues, while maintaining regulation of PV module voltage and average inductor current, this paper proposes to adopt a non-linear controller designed with the feedback linearization control (FLC) technique. The control laws are derived and implemented in a non-inverting buck-boost dc module integrated converter, as this is a favorite topology for the PV interfacing application. A digitally controlled converter prototype is built and used to obtain experimental results, where the FLC technique is compared with a linear cascaded control technique. The results confirm the superior performance of the presented FLC technique, which is robust and able to regulate the converter input voltage with fast and consistent dynamics, regardless of the PV module or load operating conditions. |
---|---|
ISSN: | 0885-8993 1941-0107 |
DOI: | 10.1109/TPEL.2018.2872677 |