Relationship between performance status and satisfaction with fentanyl pectin nasal spray

Background: Patients with breakthrough pain in cancer (BTPc) experience impaired activities of daily living and quality of life. Both function and satisfaction with treatment can impact patients' abilities to use products, and likely impact response to therapies. Objective: This exploratory ana...

Full description

Saved in:
Bibliographic Details
Published in:Revista de la Sociedad Española del Dolor Vol. 21; no. 4; pp. 191 - 196
Main Authors: Torres, L.M., Thorpe, D.M., Knight, A.D., Perelman, M.
Format: Journal Article
Language:English
Published: Inspira Network Group, S.L 01-08-2014
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Background: Patients with breakthrough pain in cancer (BTPc) experience impaired activities of daily living and quality of life. Both function and satisfaction with treatment can impact patients' abilities to use products, and likely impact response to therapies. Objective: This exploratory analysis examined the relationship between functional status and satisfaction with ability to use fentanyl pectin nasal spray (FPNS) for BTPc. Methods: Treatment satisfaction data were analyzed from a multicenter, open-label, long-term study using FPNS for managing BTPc in patients with Eastern Cooperative Oncology Group (ECOG) grade ≤ 2. Satisfaction with ease of use, convenience, and reliability of FPNS were assessed on three-question, four-point scales (1 = not satisfied, 2 = not satisfied or dissatisfied, 3 = satisfied, 4 = very satisfied) at the end of 1, 4, 8, and 12 weeks. For each domain, percentage of patients who reported being "satisfied or very satisfied" (score 3 or 4) with FPNS was analyzed based on ECOG grade. Results: Overall, > 90 % of patients with ECOG 0-2 reported being satisfied or very satisfied with FPNS across all three domains. Differences in patient satisfaction with FPNS by ECOG grade were clinically small though statistically significant (ease of use: p = 0.0022, convenience: p = 0.0057, and reliability: p = 0.0012). Conclusion: The FPNS device was well accepted irrespective of ECOG grade (0-2). Statistically, patients with higher performance status (lower ECOG grades) reported higher satisfaction scores, though effect size was small. Results imply the FPNS device provides a high level of usability irrespective of functional status, which is likely to promote use and thus likelihood of success in controlling BTPc.
ISSN:1134-8046
DOI:10.4321/S1134-80462014000400002