Optimal Phase Load Balancing in Low Voltage Distribution Networks Using a Smart Meter Data-Based Algorithm

In the electric distribution systems, the “Smart Grid” concept is implemented to encourage energy savings and integration of the innovative technologies, helping the distribution network operators (DNOs) in choosing the investment plans which lead to the optimal operation of the networks and increas...

Full description

Saved in:
Bibliographic Details
Published in:Mathematics (Basel) Vol. 8; no. 4; p. 549
Main Authors: Grigoraș, Gheorghe, Neagu, Bogdan-Constantin, Gavrilaș, Mihai, Triștiu, Ion, Bulac, Constantin
Format: Journal Article
Language:English
Published: MDPI AG 01-04-2020
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In the electric distribution systems, the “Smart Grid” concept is implemented to encourage energy savings and integration of the innovative technologies, helping the distribution network operators (DNOs) in choosing the investment plans which lead to the optimal operation of the networks and increasing the energy efficiency. In this context, a new phase load balancing algorithm was proposed to be implemented in the low voltage distribution networks with hybrid structures of the consumption points (switchable and non-switchable consumers). It can work in both operation modes (real-time and off-line), uploading information from different databases of the DNO which contain: The consumers’ characteristics, the real loads of the consumers integrated into the smart metering system (SMS), and the typical load profiles for the consumers non-integrated in the SMS. The algorithm was tested in a real network, having a hybrid structure of the consumption points, on a by 24-h interval. The obtained results were analyzed and compared with other algorithms from the heuristic (minimum count of loads adjustment algorithm) and the metaheuristic (particle swarm optimization and genetic algorithms) categories. The best performances were provided by the proposed algorithm, such that the unbalance coefficient had the smallest value (1.0017). The phase load balancing led to the following technical effects: decrease of the average current in the neutral conductor and the energy losses with 94%, respectively 61.75%, and increase of the minimum value of the phase voltage at the farthest pillar with 7.14%, compared to the unbalanced case.
ISSN:2227-7390
2227-7390