Drift chamber for the CMD-3 detector
The construction, digitizing electronics and results of test with cosmic rays of cylindrical drift chamber for CMD-3 detector are described. To uniformly fill the sensitive volume small hexagonal cells were chosen. The coordinate along the wire is measured by charge division technique. A resolution...
Saved in:
Published in: | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Vol. 623; no. 1; pp. 114 - 116 |
---|---|
Main Authors: | , , , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Elsevier B.V
01-11-2010
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The construction, digitizing electronics and results of test with cosmic rays of cylindrical drift chamber for CMD-3 detector are described. To uniformly fill the sensitive volume small hexagonal cells were chosen. The coordinate along the wire is measured by charge division technique. A resolution in the R–ϕ-plane of better than 110μm and about 3mm along the wire as well as a dE/dx resolution of about 12% were obtained in cosmic test runs. |
---|---|