Variations in cardiac implantable electronic device surveillance and ancillary testing in the paediatric and congenital heart disease population: an international multi-centre survey from the Paediatric and Congenital Electrophysiology Society

Expert guidance from scientific societies and regulatory agencies recommend a framework of principles for frequency of in-person evaluations and remote monitoring for patients with cardiac implantable electronic devices. However, there are limited data regarding adherence to recommendations among pa...

Full description

Saved in:
Bibliographic Details
Published in:Cardiology in the young Vol. 32; no. 1; p. 101
Main Authors: Olen, Melissa M, Dechert, Brynn E, Foster, Anne, Kanter, Ronald J, Silka, Michael J, Shah, Maully J
Format: Journal Article
Language:English
Published: England 01-01-2022
Subjects:
Online Access:Get more information
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Expert guidance from scientific societies and regulatory agencies recommend a framework of principles for frequency of in-person evaluations and remote monitoring for patients with cardiac implantable electronic devices. However, there are limited data regarding adherence to recommendations among paediatric electrophysiologists, and there are no data regarding cardiac implantable electronic device-related ancillary testing. To assess current clinical practices for cardiac implantable electronic device in-person evaluation, remote monitoring, and cardiac implantable electronic device-related ancillary testing, the Paediatric and Congenital Electrophysiology Society members were surveyed. The main outcome measures were variations in frequency of in person evaluation, frequency of remote monitoring, and cardiac implantable electronic device-related ancillary testing. All respondents performed in-person evaluation at least once a year, but <50% of respondents performed an in-person evaluation within 2 weeks of cardiac implantable electronic device implantation. Remote monitoring was performed every 3 months for pacemakers and implantable cardioverter defibrillators by 71 and 75% respondents, respectively. Follow-up echocardiography was performed every 2-3 years by 53% respondents for patients with >50% ventricular pacing. Majority of respondents (75%) did not perform either an exercise stress test or ambulatory Holter monitoring or chest X-ray (65%) after cardiac implantable electronic device implantation. This survey identified significant practice variations in cardiac implantable electronic device in- person evaluation, remote monitoring, and ancillary testing practices among paediatric electrophysiologists. Cardiac implantable electronic device management may be optimised by development of a paediatric-specific guidelines for follow-up and ancillary testing.
ISSN:1467-1107
DOI:10.1017/S104795112100425X