Radial position sensing in a coplanar-grid high-pressure xenon gamma-ray spectrometer

This paper describes a technique for determining the interaction radius of a gamma ray within a cylindrical detector. This can be useful information for correcting pulse amplitudes and selecting events of interest. A theoretical expression for the event radius is derived based on anode signals, and...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on nuclear science Vol. 53; no. 3; pp. 1380 - 1384
Main Authors: Kiff, S.D., Zhong He, Tepper, G.C.
Format: Journal Article
Language:English
Published: New York IEEE 01-06-2006
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:This paper describes a technique for determining the interaction radius of a gamma ray within a cylindrical detector. This can be useful information for correcting pulse amplitudes and selecting events of interest. A theoretical expression for the event radius is derived based on anode signals, and simulations are compared with experimental results.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:0018-9499
1558-1578
DOI:10.1109/TNS.2006.875152