Genetic Algorithm-Based Optimal Sizing of Hybrid Battery/Ultracapacitor Energy Storage System for Wave Energy Harvesting Applications

The output power of an ocean wave energy (WE) system has an intermittent and stochastic characteristic. WE output power can be transferred to the grid without sudden fluctuations when combined with a hybrid energy storage system (HESS) consisting of a battery pack and an ultracapacitor (UC) module....

Full description

Saved in:
Bibliographic Details
Published in:IEEE access Vol. 12; pp. 125572 - 125584
Main Authors: Aktas, Ahmet, Onar, Omer C., Asa, Erdem, Ozpineci, Burak, Tolbert, Leon M.
Format: Journal Article
Language:English
Published: Piscataway IEEE 01-01-2024
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The output power of an ocean wave energy (WE) system has an intermittent and stochastic characteristic. WE output power can be transferred to the grid without sudden fluctuations when combined with a hybrid energy storage system (HESS) consisting of a battery pack and an ultracapacitor (UC) module. The study presented in this paper identifies the lowest-cost HESS sizing for WE systems by using a genetic algorithm (GA) optimization method. In this study, the system cost was reduced with the HESS cost and sizing study for ocean WE converter systems, and the battery was used effectively for a longer cycle. GA optimization has been applied in the field of HESS in ocean WE systems and has brought innovation to the literature with its optimum cost and sizing study. An optimum design model is presented considering the maximum/minimum voltage and current limits and the energy storage units' temperature and depth of discharge parameters. The series and parallel connection calculations and the required number of battery and UC cells are given in the sizing section. The GA optimization was performed in Matlab, and the energy storage rate for the 625-kW system and the power and energy results of the energy storage units were given as a result of the optimum cost analysis. It has been calculated that 15936 battery cells are normally required for a 625-kW ocean WE converter system. As a result of the proposed optimally sized, cost-effective HESS, it is presented that a hybrid energy system can be used at a lower cost with 5548 battery cells and 2125 UC cells for the same performance and functionality.
Bibliography:USDOE Office of Energy Efficiency and Renewable Energy (EERE)
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Renewable Power Office. Water Power Technologies Office
AC05-00OR22725
ISSN:2169-3536
2169-3536
DOI:10.1109/ACCESS.2024.3414433