Intimal hyperplasia within biliary Wallstents: failure of recanalisation by insertion of a second endoprosthesis

We report two patients with benign biliary strictures in whom we attempted recanalisation of metallic biliary endoprostheses, occluded by intimal hyperplasia, by the insertion of further endoprostheses within the occluded stents. Initial technical success was achieved in deploying the stents and res...

Full description

Saved in:
Bibliographic Details
Published in:European radiology Vol. 9; no. 4; pp. 630 - 633
Main Authors: McKeown, B J, Wong, W L, Jackson, B T, Benjamin, I S, Jeer, P, Adam, A
Format: Journal Article
Language:English
Published: Germany Springer Nature B.V 01-01-1999
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We report two patients with benign biliary strictures in whom we attempted recanalisation of metallic biliary endoprostheses, occluded by intimal hyperplasia, by the insertion of further endoprostheses within the occluded stents. Initial technical success was achieved in deploying the stents and restoring patency with elimination of mural filling defects. However, we found the intimal hyperplasia to be restrained for less than 48 h. From our initial results it appears that biliary metallic stent occlusion by intimal hyperplasia is not effectively treated by insertion of a second endoprosthesis.