Frequency of Positive Cuff Leak Test Before Extubation in Robotic Surgeries Done in Steep Trendelenburg Position

Anaesthesia for robotic surgeries done in steep trendelenburg position are associated with risks such as facial oedema, conjunctival chemosis, raised intraocular pressure, laryngeal oedema, and delayed awakening. We proposed the use of the cuff leak test in them to record the frequency of laryngeal...

Full description

Saved in:
Bibliographic Details
Published in:Indian journal of surgical oncology Vol. 13; no. 4; pp. 896 - 901
Main Authors: Bajaj, Jhanvi S., Sharma, Sudivya, Mehta, Niyati, Shah, Akshat, Nimje, Ganesh, Gorade, Manoj, Deshpande, Gargi
Format: Journal Article
Language:English
Published: New Delhi Springer India 01-12-2022
Springer Nature B.V
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Anaesthesia for robotic surgeries done in steep trendelenburg position are associated with risks such as facial oedema, conjunctival chemosis, raised intraocular pressure, laryngeal oedema, and delayed awakening. We proposed the use of the cuff leak test in them to record the frequency of laryngeal oedema at the end of surgery and attempted to find its correlation with probable risk factors. We conducted a prospective observational study of 100 patients aiming primarily to assess the frequency of positive cuff leak test in robotic abdominal surgeries performed in trendelenburg position. The secondary outcomes were to check its correlation with intravenous fluid administration, duration of pneumoperitoneum, and angle of trendelenburg position. We also recorded the frequency of chemosis, the frequency of post-extubation stridor in 24 h post-operatively, and the frequency of reintubation. Out of 100 participants undergoing elective abdominal robotic surgery in trendelenburg position, ninety were analysed. Total 31.6% ( n  = 30) participants showed positive cuff leak test. Chemosis was observed in 31 (32.6%) participants. No patient experienced post-extubation stridor or required reintubation during post-operative follow up. There was a no correlation between cuff leak test and intravenous fluid, duration of pneumo-peritoneum, or with angle of trendelenburg. The frequency of positive cuff leak test was high in patients at the end of robotic surgery but none of these patients had post-extubation stridor or required reintubations. There was no correlation with the fluid, angle, or duration of surgery. Clinical Trials Registry of India (CTRI/2017/04/008289), ctri.nic.in.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0975-7651
0976-6952
DOI:10.1007/s13193-022-01605-8