Comprehensive Comparison of Image Quality Aspects Between Conventional and Plane-Wave Imaging Methods on a Commercial Scanner

Coherent plane-wave compound imaging (CPWCI) is used as alternative for conventional focused imaging (CFI) to increase frame rates linearly with the ratio number of imaging lines to steering angles. In this study, the image quality was compared between CPWCI and CFI, and the effect of steering angle...

Full description

Saved in:
Bibliographic Details
Published in:IEEE transactions on ultrasonics, ferroelectrics, and frequency control Vol. 69; no. 6; pp. 2039 - 2049
Main Authors: Hendriks, Gijs A. G. M., Weijers, Gert, Chen, Chuan, Hertel, Madeleine, Lee, Chi-Yin, Dueppenbecker, Peter M., Radicke, Marcus, Milkowski, Andy, Hansen, Hendrik H. G., de Korte, Chris L.
Format: Journal Article
Language:English
Published: United States IEEE 01-06-2022
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Coherent plane-wave compound imaging (CPWCI) is used as alternative for conventional focused imaging (CFI) to increase frame rates linearly with the ratio number of imaging lines to steering angles. In this study, the image quality was compared between CPWCI and CFI, and the effect of steering angles (range and number) and beamforming strategies was evaluated in CPWCI. In automated breast volume scanners (ABVSs), which suffer from reduced volume rates, CPWCI might be an excellent candidate to replace CFI. Therefore, the image quality of CFI currently in ABVS and CPWCI was also compared in an in vivo breast lesion. Images were obtained by a Siemens Sequoia ultrasound system, and two transducers (14L5 and 10L4) in a CIRS multipurpose phantom (040GSE) and a breast lesion. Phantom results showed that contrast sensitivity and resolution, axial resolution, and generalized contrast-to-noise ratio (gCNR; imaging depths <45 mm) were similar for most imaging sequences. CNR (imaging depths ≥45 mm), penetration, and lateral resolution were significantly improved for CPWCI (15 angles) compared to CFI for both transducers. In CPWCI, certain combinations of steering angles and beamforming methods yielded improved gCNR (small angles and delay-and-sum) or lateral resolution (large angles and Lu's-fk). Image quality seemed similar between CPWCI and CFI (three angles incoherent compounded as in ABVS) by visual inspection of the in vivo breast lesion images.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0885-3010
1525-8955
DOI:10.1109/TUFFC.2022.3165632