Cathode image readout in the BELLE central drift chamber
We report on the design and construction of the cathode image readout section of the BELLE detector's central drift chamber. The cathode information is used for measurements of charged particle trajectory coordinates along the beam axis and the charged-track trigger. The performance is evaluate...
Saved in:
Published in: | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Vol. 454; no. 2; pp. 322 - 333 |
---|---|
Main Authors: | , , , , , , , , , , , , , , , , , , , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Elsevier B.V
11-11-2000
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | We report on the design and construction of the cathode image readout section of the BELLE detector's central drift chamber. The cathode information is used for measurements of charged particle trajectory coordinates along the beam axis and the charged-track trigger. The performance is evaluated with cosmic rays using the BELLE standard readout electronics and software. The detection efficiency in nominal conditions is found to exceed 98% and the position resolution for normal incidence is about 350
μm, which satisfies the design goals of the BELLE detector. |
---|---|
ISSN: | 0168-9002 1872-9576 |
DOI: | 10.1016/S0168-9002(00)00487-3 |