4-Sided irradiation systems for electron treatment of cable and pipe-like products
A 4-sided system of irradiation is described which enables one to combine high quality of irradiation with high efficiency of beam usage. Maximum homogeneity and minimum energy of electrons for a given thickness of insulation is achieved with the use of this irradiation system. The operation princip...
Saved in:
Published in: | Vacuum Vol. 62; no. 2; pp. 257 - 262 |
---|---|
Main Authors: | , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Elsevier Ltd
15-06-2001
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A 4-sided system of irradiation is described which enables one to combine high quality of irradiation with high efficiency of beam usage. Maximum homogeneity and minimum energy of electrons for a given thickness of insulation is achieved with the use of this irradiation system. The operation principle of the device is based on the deflection of an electron beam by a magnetic field. It changes electron trajectories so that, regardless of the input point, all electrons passing the left-hand magnet have an angle with the vertical axis of −45°±5° and for the right-hand magnet +45°±5°, so the beam trajectories intersect at an angle of 90°. The cable is placed under the beam in such a way that the upper and lower surfaces of the cable are changed at each turn so that, taking into account this change of surfaces, we obtain a 4-sided irradiation. Two versions of the universal system of cable irradiation are suggested in this paper. The methods have been designed for use on the ELV-series of accelerators. |
---|---|
ISSN: | 0042-207X 1879-2715 |
DOI: | 10.1016/S0042-207X(01)00218-4 |