B-mode Real Time Ultrasonographic imaging of the Heart in Sheep

The anatomical structure of normal heart was studied in vitro through ultrasonography of 27 healthy hearts of sheep collected following slaughter. Ultrasonography was done in the water with 25o C by sectorial transducer from 2 cm distance. In the laboratory, the waves of ultrasonography were sent fr...

Full description

Saved in:
Bibliographic Details
Published in:Veterinary World Vol. 4; no. 10; pp. 467 - 469
Main Author: Aissi, A
Format: Journal Article
Language:English
Published: Rajkot Veterinary World 01-10-2011
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The anatomical structure of normal heart was studied in vitro through ultrasonography of 27 healthy hearts of sheep collected following slaughter. Ultrasonography was done in the water with 25o C by sectorial transducer from 2 cm distance. In the laboratory, the waves of ultrasonography were sent from right ventricle (RV). The thickness of left ventricle wall (LV) (20.69±2.628mm), right ventricle wall (RV) (8.10±2.138mm) and inter ventricular space (IVS) (18.925±1.984mm) were measured by ultrasonography. After preparing ultrasonogrphes obtained by in vitro ultrasonography were compared with natural anatomical views. Also biometrical measurements were compared with sizes were measured by ultrasonography measurement. Biometrical measurements were performed by a special ruler (caliper) right ventricle thickness (7.6±1.957mm), left ventricle thickness (19.20±1.563mm) and inter-ventricular space thickness is (17.981±1.786mm).