Experience with Using Heat-Resistant Chromium-Aluminum Steel for the Gas-Intake Shafts of Tract L in the Kharanor State Regional Power Plant

Positive experience has been gained in using shells of heat-resistant 03Kh18Yu3BT steel with external insulation instead of shells of St3 sheet steel with an inner layer of concrete or fireclay brick for the gas-intake shafts of tract L at the Kharanor State Regional Power Plant (GRÉS). The new gas-...

Full description

Saved in:
Bibliographic Details
Published in:Power technology and engineering Vol. 49; no. 1; pp. 50 - 52
Main Authors: Skorobogatykh, V. N., Ershov, N. S., Orlov, A. S., Tronev, V. I.
Format: Journal Article
Language:English
Published: New York Springer US 01-05-2015
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Positive experience has been gained in using shells of heat-resistant 03Kh18Yu3BT steel with external insulation instead of shells of St3 sheet steel with an inner layer of concrete or fireclay brick for the gas-intake shafts of tract L at the Kharanor State Regional Power Plant (GRÉS). The new gas-intake shafts have made it possible to reduce the weight of the structure by a factor of 3 – 4 and maintenance is less complicated.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1570-145X
1570-1468