Amplitude and time spectra of a drift tube (DT) were investigated using cosmic radiation at different voltages applied to it and different compositions of an Ar + CO 2 gas mixture. The dependence of the drift time on the CO 2 concentration was studied. The mode of DT response mainly to the first clu...

Full description

Saved in:
Bibliographic Details
Published in:Instruments and experimental techniques (New York) Vol. 58; no. 6; pp. 719 - 725
Main Authors: Bogolyubsky, M. Yu, Kalinin, A. Yu, Krinitsyn, A. N., Morshinov, A. A., Talov, V. V., Turchanovich, L. K.
Format: Journal Article
Language:English
Published: Moscow Pleiades Publishing 01-11-2015
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Amplitude and time spectra of a drift tube (DT) were investigated using cosmic radiation at different voltages applied to it and different compositions of an Ar + CO 2 gas mixture. The dependence of the drift time on the CO 2 concentration was studied. The mode of DT response mainly to the first cluster was selected. The working point for the high voltage applied to the tube was determined. It was shown that the spatial resolution of a DT for the FODS tracking system for cosmic events is ~0.5 mm.