Current distribution in a liquid electrospray system with two counter-electrodes

We have experimentally studied the distribution of current in an electrospray system with two counter-electrodes. It is established that, at low values of the total current, its distribution between these electrodes is proportional to the electric field flux to a given electrode. As the total curren...

Full description

Saved in:
Bibliographic Details
Published in:Technical physics letters Vol. 43; no. 5; pp. 490 - 492
Main Authors: Gromov, I. A., Samsonova, N. S., Gall, L. N., Gall, N. R.
Format: Journal Article
Language:English
Published: Moscow Pleiades Publishing 01-05-2017
Springer Nature B.V
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:We have experimentally studied the distribution of current in an electrospray system with two counter-electrodes. It is established that, at low values of the total current, its distribution between these electrodes is proportional to the electric field flux to a given electrode. As the total current grows, this proportionality changes toward more uniform distribution, probably, due to increased role of a space charge producing mutual repulsion of charged particles.
ISSN:1063-7850
1090-6533