434 Ionizing radiation acoustic imaging (iRAI) for volumetric mapping the dose deep in the liver during radiation therapy
OBJECTIVES/GOALS: The goal of this study was to develop a clinically applicable technique to increase the precision of in vivo dose monitoring during radiation therapy by mapping the dose deposition and resolving the temporal dose accumulation while the treatment is being delivered in real time. MET...
Saved in:
Published in: | Journal of clinical and translational science Vol. 7; no. s1; p. 129 |
---|---|
Main Authors: | , , , , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Cambridge
Cambridge University Press
01-04-2023
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | OBJECTIVES/GOALS: The goal of this study was to develop a clinically applicable technique to increase the precision of in vivo dose monitoring during radiation therapy by mapping the dose deposition and resolving the temporal dose accumulation while the treatment is being delivered in real time. METHODS/STUDY POPULATION: Ironizing radiation acoustic imaging (iRAI) is a novel imaging concept with the potential to map the delivered radiation dose on anatomic structure in real time during external beam radiation therapy without interrupting the clinical workflow. The iRAI system consisted of a custom-designed two-dimensional (2D) matrix transducer array with integrated preamplifier array, driven by a clinic-ready ultrasound imaging platform. The feasibility of iRAI volumetric imaging in mapping dose delivery and real-time monitoring of temporal dose accumulation in a clinical treatment plan were investigated with a phantom, a rabbit model, and a cancer patient. RESULTS/ANTICIPATED RESULTS: The total dose deposition and temporal dose accumulation in 3D space of a clinical C-shape treatment plan in a targeted region were first imaged and optimized in a phantom. Then, semi-quantitative iRAI measurements were achieved in an in vivo rabbit model. Finally, for the first time, real-time visualization of radiation dose delivered deep in a patient with liver metastases was performed with a clinical linear accelerator. These studies demonstrate the potential of iRAI to monitor and quantify the radiation dose deposition during treatment. DISCUSSION/SIGNIFICANCE: Described here is the pioneering role of an iRAI system in mapping the 3D radiation dose deposition of a complex clinical radiotherapy treatment plan. iRAI offers a cost-effective and practical solution for real-time visualization of 3D radiation dose delivery, potentially leading to personalized radiotherapy with optimal efficacy and safety. |
---|---|
ISSN: | 2059-8661 2059-8661 |
DOI: | 10.1017/cts.2023.463 |