Effect of (50 % Isopropanol–30 % Methanol–17 % Xylene) mixture on corrosion behavior of pure Al and its alloys in simulated fuel
This work involves studying the effect of adding (50 %Isopropanol–30 % Methanol–17 %Xylene) mixture on corrosion behavior of pure Al and its alloys in simulated fuel at room temperature. The results of electrochemical measurements indicate that the addition of this mixture lead to decreasing in corr...
Saved in:
Published in: | Engineering and Technology Journal Vol. 32; no. 6A; pp. 1380 - 1389 |
---|---|
Main Authors: | , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Baghdad, Iraq
University of Technology
01-07-2014
Unviversity of Technology- Iraq |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This work involves studying the effect of adding (50 %Isopropanol–30 % Methanol–17 %Xylene) mixture on corrosion behavior of pure Al and its alloys in simulated fuel at room temperature. The results of electrochemical measurements indicate that the addition of this mixture lead to decreasing in corrosion rate values for pure Al and its alloys. Electrochemical measurements were carried out by potentiostat at weep rate of 3 mV / sec to estimate the corrosion parameters using Tafel extrapolation method, in addition to cyclic polarization test to know the pitting susceptibility of materials in tested medium. Generally, the cathodic Tafel slope (bc) were increased after adding mixture. But the anodic Tafel slopes (ba) were decreased except for Al-Cu alloy. The small anodic slope indicates the presence of a film on the surface of the tested material, which is less permeable and can even obstruct the metal dissolution reaction but still permits an electrochemical reaction to occur. This behavior can be achieved by the electronic density on oxygen atoms in alcohols.
یتضمن ھذا البحث دراسة تأثیر إضافة خلیط (50% Isopropanol – 30% Methanol – 17% Xylene) على السلوك التآكلي للألمنیوم النقي و سبائكه في الوقود المحضر مختبریا عند درجة حرارة الغرفة، و تبین نتائج القیاسات الكھروكیمیائیة بأن إضافة ھذا الخلیط تؤدي إلى تقلیل معدل سرعة التآكل للالمنیوم النقي و سبائكه.
أجریت القیاسات الكھروكیمیائیة بالمجھاد الساكن عند معدل مسح 3 ملي فولت لكل ثانیة لتقدیر متغیرات التآكل بطریقة تافل الاستقرائیة بالإضافة إلى اختبار المنحني الحلقي لمعرفة حساسیة المادة للتنقر في الوسط المحضر. لوحظ عموما بأن میول تافل الكاثودیة ازدادت بعد إضافة الخلیط و أن میول تافل الانودیة قد قلت ما عدا لسبیكة المنیوم - نحاس. إن النقصان في میل تافل الانودي یدل على وجود غشاء واقي على سطح المادة المعدنیة و الذي یكون أقل نفاذیة و یعیق تفاعل الذوبان المعدني و تلعب الكثافة الإلكترونیة على ذرات الأوكسجین في الكحول دورا كبیرا في تعزیز الغشاء الواقي. |
---|---|