Measurement of time correlated photoelectric and Compton events of gamma rays using advanced detectors

With the advancement of the detector systems for γ-ray radiation, simultaneous measurement of time correlated photoelectric and Compton events recorded by employing segmented HPGe detectors (Clover Detectors) with very high energy resolution and efficiency, allows measuring the polarization of the γ...

Full description

Saved in:
Bibliographic Details
Published in:Journal of radioanalytical and nuclear chemistry Vol. 333; no. 11; pp. 5399 - 5405
Main Authors: Gupta, A. K., Rana, A. K., Anser, Md, Sharma, Ishika, Tiwary, S. S., Sharma, H. P.
Format: Journal Article
Language:English
Published: Cham Springer International Publishing 01-11-2024
Springer Nature B.V
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:With the advancement of the detector systems for γ-ray radiation, simultaneous measurement of time correlated photoelectric and Compton events recorded by employing segmented HPGe detectors (Clover Detectors) with very high energy resolution and efficiency, allows measuring the polarization of the γ-ray radiation in addition to the energy of the γ-ray radiation. The polarization measurement of the γ-ray radiation provides information regarding its electric or magnetic nature, which is essential for determining the parity of the decaying nuclear state. Data is shown for the low laying  states of 136 Ce with information on  the R DCO and polarization measurements. These measurements were carried out with the help of Indian National Gamma Array (INGA), New Delhi setup.
ISSN:0236-5731
1588-2780