Objective: To determine the anatomical characteristics of Patent Ductus Arteriosus, choice of transcatheter occluder device and outcomes of Patent Ductus Arteriosus device closure. Study Design: Analytical Cross-sectional study. Place and Duration of Study: Paediatric Cardiology Department, Armed Fo...
Saved in:
Published in: | Pakistan Armed Forces medical journal Vol. 74; no. SUPPL-1; pp. S62 - S67 |
---|---|
Main Authors: | , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Rawalpindi
Knowledge Bylanes
30-06-2024
AsiaNet Pakistan (Pvt) Ltd |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Objective: To determine the anatomical characteristics of Patent Ductus Arteriosus, choice of transcatheter occluder device and outcomes of Patent Ductus Arteriosus device closure.
Study Design: Analytical Cross-sectional study.
Place and Duration of Study: Paediatric Cardiology Department, Armed Forces Institute of Cardiology/National Institute of Heart Diseases, Rawalpindi Pakistan, from Jan-July 2023.
Methodology: A total of n=90 patients regardless of age and gender presenting with Patent Ductus Arteriosus, who underwent device closure were enrolled in this study by universal sampling. Data of the patients was collected on pre-designed proforma. Pearson's Chi-square test was applied to find association of morphological type of ductus and the weight of patient with the type of device used. p-value < 0.05 was considered as statistically significant.
Results: Among n=90 patients, 56(62.2%) were females and 34(37.8%) were males with median age of 1(IQR=0.6-4.25) years who underwent transcatheter device closure. The most common ductus types treated were Krichenko type-A 70(76.7%). Devices used were VSD device 15(16.7%), ADO-II 6(6.7%) and ADO-I device (conventional duct occluder) 69(76.7%). Median fluoroscopy time was 8.40(7.2-12.07) minutes. Statistically significant relationships were observed between Krichenko classification of Patent Ductus Arteriosus, weight of patient and type of device used to occlude the Patent Ductus Arteriosus (p<0.001). Success rate was 88(97.7%). Complications occurred in only 2(2.2%) patients in the form of device embolization. In 1(1.1%) patient, embolized device was retrieved while, the other patient was referred for surgical retrieval.
Conclusion: Transcatheter Patent Ductus Arteriosus device closure is a standard and safe procedure for closure of ductus with vari.. |
---|---|