The three-dimensional reconstruction of the dilated renal pelvicalyceal system by non-enhanced computed tomography

Introduction. The three-dimensional reconstruction of the renal pelvicalyceal system (PCS) is possible when performing enhanced computed tomography (CT). However, the use of a contrast agent has its limitations associated with the presence of allergy and chronic kidney disease. Purpose of the study....

Full description

Saved in:
Bibliographic Details
Published in:Vestnik urologii (Online) Vol. 9; no. 3; pp. 19 - 24
Main Authors: Guliev, B. G., Komyakov, B. K., Talyshinskiy, A. E.
Format: Journal Article
Language:English
Russian
Published: State Budget Educational Institute of Higher Professional Education, Rostov State Medical University, Ministry Health of Russian Federation 05-10-2021
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Introduction. The three-dimensional reconstruction of the renal pelvicalyceal system (PCS) is possible when performing enhanced computed tomography (CT). However, the use of a contrast agent has its limitations associated with the presence of allergy and chronic kidney disease. Purpose of the study. To describe the method of semi-autonomous three-dimensional (3D) reconstruction of the PCS based on non-enhanced CT images of patients with upper urinary tract obstruction. Materials and methods. Five patients diagnosed with renal colic were recruited from April-May 2021. All patients underwent CT-urography after informed consent. Medical Imaging Interaction Toolkit program (MITK) expanded with explainable update were used for 3D-reconstruction of PCS via excretory and native phases. To assess the accuracy of the latter, both contrast and non-contrast models were compared regarding their surface area. Also, the PCS of one patient was used to reconstruct virtual endoscopic views based on enhanced and non-enhanced models. Five urologists estimated their similarity and potential use of non-enhanced models for the interventional planning via a Likert scale questionnaire. The resulting models were also analyzed by programmer-engineers to test their suitability for 3D-printing. Results. The average surface area of enhanced and non-enhanced models was 3291 mm 2 and 2879 mm 2 , respectively. Obtained models were suitable for their intraluminal reconstruction and potential 3D-printing. Analyzed properties of non-enhanced models were estimated at 4.5 out of 5.0. Conclusion. The described semi-autonomous reconstruction of the renal PCS based on non-enhanced CT images allows for a short time to reconstruct its 3D-view in patients with the upper urinary tract obstruction.
ISSN:2308-6424
2308-6424
DOI:10.21886/2308-6424-2021-9-3-19-24