Objective The goal of this study was to examine the theoretical feasibility of a new manipulator system for endoscope guidance in functional endoscopic sinus surgery. Study Design The accuracy of endoscope positioning and time of endoscope movement with an endoscope manipulator system were determine...

Full description

Saved in:
Bibliographic Details
Published in:Otolaryngology-head and neck surgery Vol. 145; no. 5; pp. 833 - 839
Main Authors: Fischer, Miloš, Gröbner, Christina, Dietz, Andreas, Krinninger, Maximillian, Lüth, Tim C., Strauß, Gero
Format: Journal Article
Language:English
Published: Sage CA: Los Angeles, CA SAGE Publications 01-11-2011
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Objective The goal of this study was to examine the theoretical feasibility of a new manipulator system for endoscope guidance in functional endoscopic sinus surgery. Study Design The accuracy of endoscope positioning and time of endoscope movement with an endoscope manipulator system were determined with an artificial sinus model. Setting A laboratory trial was performed. The time for 60 repetitions of manual compared to manipulator‐assisted endoscope movements directed at 3 different target positions was evaluated. In addition, the alignment of the position vector for each endoscope movement was examined. Subjects and Methods A zero‐degree Hopkins II telescope with a camera was used to head for the target positions. First, the endoscope movements were done manually, and afterward the endoscope manipulator system was used for endoscope guidance. The alignment of the position vector of the endoscope was measured with a portable measuring arm. Results There was no statistical difference between the time for manual and manipulator‐assisted endoscope movements for all target positions. The alignment of the position vector of the endoscope was statistically different at 2 target positions: anterior ethmoid left side and ostium of maxillary sinus left side. There was no statistical difference at all other positions. Conclusion The endoscope manipulator system has the potential to be integrated into the operating workflow without extending the time for endoscope guidance. The surgeon will be able to use both hands for the manipulation of the instruments. Less frequent endoscope movements and instrument changes may be expected after technical modification.
Bibliography:The results of this study were presented as a scientific session at the 2010 AAO‐HNSF Annual Meeting & OTO EXPO; September 26‐29, 2010; Boston, Massachusetts.
Sponsorships or competing interests that may be relevant to content are disclosed at the end of this article.
ISSN:0194-5998
1097-6817
DOI:10.1177/0194599811412726