645. Singulex Clarity Norovirus Assay (In Development) Provides Ultrasensitive Detection of Norovirus Genogroups I and II

Abstract Background Commercially available enzyme immunoassays (EIAs) for detection of norovirus antigen have poor sensitivity and are limited to use in investigations of a gastroenteritis outbreak. Hence, there remains a need for a standalone high-sensitivity assay that enables rapid and accurate d...

Full description

Saved in:
Bibliographic Details
Published in:Open forum infectious diseases Vol. 6; no. Supplement_2; pp. S297 - S298
Main Authors: Dave, Gipshu, Katzenbach, Phoebe, Sandlund, Johanna, Estis, Joel, Mukherjee, Ali, Nolan, Niamh, Almazan, Anna, Hadass, Orr, Noland, Brian, Bishop, Jeffrey J, Banaei, Niaz, Riner, Diana K, Todd, John
Format: Journal Article
Language:English
Published: US Oxford University Press 23-10-2019
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Background Commercially available enzyme immunoassays (EIAs) for detection of norovirus antigen have poor sensitivity and are limited to use in investigations of a gastroenteritis outbreak. Hence, there remains a need for a standalone high-sensitivity assay that enables rapid and accurate detection of norovirus antigen. Methods The Singulex Clarity norovirus assay is currently in development for use on the Singulex Clarity® system (Singulex Inc., Alameda, CA, USA), a fully-automated platform powered by Single Molecule Counting technology (registered with the FDA and CE marked). The assay uses paramagnetic microparticles bound to capture antibody and a fluorescently labeled reporter antibody to detect virion capsid protein of norovirus genogroups I (GI) and II (GII) in the stool. For the development of Clarity Norovirus assay, diagnostic performance of 4 antibody pairs (as Capture and Detection reagent) were evaluated by testing 137 stool samples from patients with suspected norovirus infection. Samples were sourced from three providers: (1) 90 genotyped samples of which 75 were positive (19 different genotypes) and 15 were negative by the CDC assay, (2) 3 samples positive and 5 samples negative by the BioFire® FilmArray® Gastrointestinal Panel, and (3) 39 samples negative by a lab-developed test using Cepheid reagents (SmartCycler®). Results From all the antibody pairs tested, one of the pairs had best performance with the area under the receiver operating characteristic (AuROC) curve demonstrating a C-Statistic of 0.959 (95% CI 0.921–0.997), compared with AuROC C-statistic of 0.943 (95% CI 0.896–0.990), 0.871 (95% CI 0.807–0.936), and 0.914 (95% CI 0.863–0.964) for the three other pairs. The Clarity assay detected all 19 different genotypes tested (figures). Conclusion The ultrasensitive and rapid Clarity norovirus assay (in development) for detection of GI and GII demonstrated excellent performance with one of the antibody pairs tested and detected all 19 tested genotypes. The Clarity assay may offer a standalone solution for norovirus diagnostics. Disclosures All authors: No reported disclosures.
ISSN:2328-8957
2328-8957
DOI:10.1093/ofid/ofz360.713