Quality of Life in Subcutaneous or Transvenous Implantable Cardioverter-Defibrillator Patients: A Secondary Analysis of the PRAETORIAN Trial
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to overcome the risk of lead-related complications associated with the transvenous implantable cardioverter-defibrillator (TV-ICD). In contrast to the TV-ICD, the S-ICD is a completely extrathoracic device. Sub...
Saved in:
Published in: | Circulation Cardiovascular quality and outcomes Vol. 17; no. 11; p. e010822 |
---|---|
Main Authors: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Hagerstown, MD
Lippincott Williams & Wilkins
01-11-2024
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to overcome the risk of lead-related complications associated with the transvenous implantable cardioverter-defibrillator (TV-ICD). In contrast to the TV-ICD, the S-ICD is a completely extrathoracic device. Subsequently, complications differ between these 2 implantable cardioverter-defibrillators, which might impact patient perceptions of the therapies. This prespecified secondary analysis of the PRAETORIAN trial evaluates differences in quality of life. METHODS: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) randomized patients with an implantable cardioverter-defibrillator indication, without the need for pacing to S-ICD or TV-ICD therapy. Two questionnaires were collected at baseline, discharge, 12 months, and 30 months. The Duke Activity Status Index measures cardiac-specific physical functioning, and the 36-Item Short Form Health Survey measures physical and mental well-being, with the subscales bodily pain and mental health being of interest in this analysis. Mann-Whitney U tests were used to compare study arms, and a mixed model was used to describe the questionnaire outcomes over time. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). In the S-ICD group, 20% were women versus 19% in the TV-ICD group. The median age was 63 (interquartile range, 54–69) years in the S-ICD group versus 64 (interquartile range, 56–69) years in the TV-ICD group. There were no significant differences in the Duke Activity Status Index and 36-Item Short Form Health Survey subscales for bodily pain and mental health between the groups at any time point. Patients with a shock in the last 90 days had significantly lower scores for social functioning ( P =0.008) and role limitations due to emotional problems ( P =0.001) than patients without a shock, but this effect did not differ between treatment arms. CONCLUSIONS: In a large randomized cohort of patients with an S-ICD or TV-ICD, no difference in overall quality of life was observed. However, implantable cardioverter-defibrillator shocks resulted in a reduction in quality of life, regardless of the device type or appropriateness. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01296022. |
---|---|
ISSN: | 1941-7713 1941-7705 |
DOI: | 10.1161/CIRCOUTCOMES.124.010822 |