Transcutaneous bilirubinometry during and after phototherapy in preterm infants: a prospective observational study
ObjectiveTo examine the accuracy of transcutaneous bilirubinometry (TCB) measurements during and after phototherapy (PT) in preterm infants.DesignProspective observational cohort study.SettingLevel III neonatal centre.PatientsPreterm infants (from 23+0 to 36+6 weeks of gestation) born between June 2...
Saved in:
Published in: | BMJ paediatrics open Vol. 4; no. 1; p. e000681 |
---|---|
Main Authors: | , , |
Format: | Journal Article |
Language: | English |
Published: |
England
BMJ Publishing Group LTD
16-07-2020
BMJ Publishing Group |
Series: | Original research |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | ObjectiveTo examine the accuracy of transcutaneous bilirubinometry (TCB) measurements during and after phototherapy (PT) in preterm infants.DesignProspective observational cohort study.SettingLevel III neonatal centre.PatientsPreterm infants (from 23+0 to 36+6 weeks of gestation) born between June 2017 and May 2018 requiring PT.InterventionsTCB was measured from an exposed area of the skin (the sternum; TCBU) and the covered area of the skin under the nappy (the bony part of the upper outer quadrant of the buttock; TCBC) within an hour of obtaining total serum bilirubin (TSB).Main outcome measuresCorrelation and agreement between TCB (TCBU and TCBC) and TSB during and after PT.ResultsWe have enrolled 196 preterm infants. There was a significant correlation between TSB and TCB during PT (r=0.72, 95% CI 0.66 to 0.77 in covered area; r=0.75, 95% CI 0.70 to 0.80 in uncovered area) and after PT (r=0.87, 95% CI 0.83 to 0.91). TCB underestimated TSB level during PT, with a mean TCBC–TSB difference of −25±43 (95% agreement limits of 62 to −112) and a mean TCBU–TSB difference of −48±46 (95% agreement limits of 45 to −140). The agreement between TCB and TSB after cessation of PT improved, with TCB underestimating TSB by a mean TCB–TSB difference of −10±31 (95% agreement limits of 52 to −72).ConclusionTCB measurements correlated strongly with TSB levels during and after PT. However, there was a wide and clinically relevant disagreement between TCB and TSB measurements during the PT phase, improving significantly after PT. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 2399-9772 2399-9772 |
DOI: | 10.1136/bmjpo-2020-000681 |