Anterior capsule contraction and intraocular lens dislocation in eyes with pseudoexfoliation syndrome

AIMS To examine the extent of anterior capsule contraction as well as intraocular lens (IOL) decentration and tilt following implant surgery in eyes with pseudoexfoliation syndrome (PE). METHODS 53 eyes from 53 patients with PE and 53 control eyes from 53 age matched patients, undergoing phacoemulsi...

Full description

Saved in:
Bibliographic Details
Published in:British journal of ophthalmology Vol. 82; no. 12; pp. 1429 - 1432
Main Authors: Hayashi, Hideyuki, Hayashi, Ken, Nakao, Fuminori, Hayashi, Fumihiko
Format: Journal Article
Language:English
Published: BMA House, Tavistock Square, London, WC1H 9JR BMJ Publishing Group Ltd 01-12-1998
BMJ
BMJ Publishing Group LTD
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:AIMS To examine the extent of anterior capsule contraction as well as intraocular lens (IOL) decentration and tilt following implant surgery in eyes with pseudoexfoliation syndrome (PE). METHODS 53 eyes from 53 patients with PE and 53 control eyes from 53 age matched patients, undergoing phacoemulsification and implant surgery, were recruited. The anterior capsule opening area and the amounts of IOL decentration and tilt after undergoing continuous curvilinear capsulorhexis were measured using the Scheimpflug videophotography system at 1 week and 1, 3, 6, 9, and 12 months postoperatively. RESULTS The mean area of the anterior capsule opening in the PE group was significantly smaller than that in the control group at 1 month postoperatively and later. The percentage reductions in the PE group were approximately 25%, while they were less than 10% in the control group. The degree of IOL tilt was also larger in the PE group than in the control group. Five eyes (9.4%) in the PE group underwent a neodymium:YAG laser anterior capsulotomy, but none in the control group underwent a capsulotomy. CONCLUSIONS The contraction of the anterior capsule opening was more extensive in the PE eyes than in the control eyes, thus resulting in a high Nd:YAG laser anterior capsulotomy rate. The IOL tilt was also greater in the PE eyes than in the control eyes.
Bibliography:istex:92BEEF09B0394B3FF9A2B052E1F2EE24F8C6CE7C
href:bjophthalmol-82-1429.pdf
local:bjophthalmol;82/12/1429
ark:/67375/NVC-HJTTWNSV-M
PMID:9930277
Hideyuki Hayashi, MD, Department of Ophthalmology, School of Medicine, Fukuoka University, Nanakuma, Jonan-ku, Fukuoka 814-01, Japan.
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0007-1161
1468-2079
DOI:10.1136/bjo.82.12.1429