Transdiaphragmatic pressure in quadriplegic individuals ventilated by diaphragmatic pacemaker

BACKGROUND: Electrophrenic pacing can be used in the management of ventilatory failure in quadriplegic patients. A study was undertaken to determine the pattern of transdiaphragmatic pressure (PDI) during the conditioning phase of electrophrenic pacing to see if it had a possible role in optimising...

Full description

Saved in:
Bibliographic Details
Published in:Thorax Vol. 51; no. 4; pp. 420 - 423
Main Authors: Garrido-García, H, Martín-Escribano, P, Palomera-Frade, J, Arroyo, O, Alonso-Calderón, J L, Mazaira-Alvarez, J
Format: Journal Article
Language:English
Published: London BMJ Publishing Group Ltd and British Thoracic Society 01-04-1996
BMJ
BMJ Publishing Group LTD
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:BACKGROUND: Electrophrenic pacing can be used in the management of ventilatory failure in quadriplegic patients. A study was undertaken to determine the pattern of transdiaphragmatic pressure (PDI) during the conditioning phase of electrophrenic pacing to see if it had a possible role in optimising the process of conditioning. METHODS: The tidal volume (TV) and PDI were measured in a group of six quadriplegic patients commencing ventilation by low frequency pulse stimulation (7-10 Hz) and low respiratory rate stimulation (< 10 breaths/min). RESULTS: Tidal volume increased between baseline and month 1 (4.33 ml/kg, p < 0.001) and between months 1 and 2 (3.00 ml/kg, p < 0.05) and then stabilised. PDI was higher during bilateral diaphragmatic pacing (mean (SD) 1.73 (0.30) kPa) than with either left (1.15 (0.34) kPa) or right (0.86 (0.37) kPa) unilateral pacing. PDI varied throughout the observation period, probably by interaction between recovery of the diaphragmatic fibres and the pacing regimen. CONCLUSIONS: Patients with quadriplegia due to high spinal injury can be maintained with ventilation by continuous electrophrenic pacing. The control criteria used in this study for pacing were tidal volume and the patient's tolerance, and the PDI measurement did not contribute any additional information to help with managing the conditioning process.
Bibliography:href:thoraxjnl-51-420.pdf
istex:6175B3C8ABFE0A2DDD0127696DB9B6B670E3308C
local:thoraxjnl;51/4/420
ark:/67375/NVC-0X266XM8-M
PMID:8733497
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0040-6376
1468-3296
DOI:10.1136/thx.51.4.420