MESOMARK@@uTM@: A Potential Test for Malignant Pleural Mesothelioma
BACKGROUND: Soluble mesothelin-related peptides (SMRP)have been reported to be potential biomarkers for malignant pleural mesothelioma (MPM). We report analytical and preliminary clinical studies of MESOMARK@@uTM@, a quantitative assay for SMRP. METHODS: The MESOMARK assay is a 2-step immunoenzymati...
Saved in:
Published in: | Clinical chemistry (Baltimore, Md.) Vol. 53; no. 4; pp. 666 - 672 |
---|---|
Main Authors: | , , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
01-04-2007
|
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | BACKGROUND: Soluble mesothelin-related peptides (SMRP)have been reported to be potential biomarkers for malignant pleural mesothelioma (MPM). We report analytical and preliminary clinical studies of MESOMARK@@uTM@, a quantitative assay for SMRP. METHODS: The MESOMARK assay is a 2-step immunoenzymatic assay in an ELISA format with a 6-point calibration curve (0-32 nmol/L). We assessed analytical imprecision, analyte stability, and analytical interferences. We measured SMRP by this assay in 409 apparently healthy individuals (reference interval study), 177 patients with nonmalignant conditions, and 500 cancer patients, including 88 with MPM. RESULTS: The limit of detection was 0.16 nmol/L. At 2-19 nmol/L, intraassay imprecision (CV) was 1.1%-5.3%, and total imprecision was 4.0%-11.0%. The mean dilution recovery for 5 samples was 109% (range, 99%-113%). No interference was seen from added bilirubin (200 mg/L), hemoglobin (500 mg/L), triglycerides (30 g/L), chemotherapeutic agents, or other tested substances. Recombinant mesothelin was stable in serum upon freeze/thaw at -70 ^'C and upon storage for at least 7 days at 2-8 ^'C. The 99@@uth@ percentile of the reference group was 1.5 nmol/L [95% confidence interval (CI), 1.2-1.6 nmol/L; n = 409], and mean SMRP was significantly higher in sera from patients with MPM (7.5 nmol/L; 95% CI, 2.8-12.1 nmol/L; n = 88). SMRP was increased in 52% and 5% of MPM patients and asbestos-exposed individuals, respectively. Concentrations in other nonmalignant and malignant conditions were similar to those in healthy controls. CONCLUSIONS: The MESOMARK assay is analytically robust and may be useful for the detection and management of mesothelioma. |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 content type line 23 ObjectType-Feature-1 |
ISSN: | 0009-9147 1530-8561 |