NONINVASIVE BIOLOGICAL PARAMETERS MEASUREMENT IN HEART PROSTHESIS
Objectives: For optimization, monitoring and partial-automation of mechanical heart support it is necessary to measure appropriate biological signals. The paper presents noninvasive measurement methods of those parameters. Goal of this study was to construct and examine selected biological parameter...
Saved in:
Published in: | International journal of artificial organs Vol. 34; no. 8; p. 612 |
---|---|
Main Authors: | , , , , , , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
01-08-2011
|
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract | Objectives: For optimization, monitoring and partial-automation of mechanical heart support it is necessary to measure appropriate biological signals. The paper presents noninvasive measurement methods of those parameters. Goal of this study was to construct and examine selected biological parameters measurement methods dedicated to pulsatile VAD. This work is a part of the Polish Artificial Heart project. Methods: The following biophysical quantities measurement methods were investigated: blood flow (ultrasound Doppler velocity profile methods), temporary blood volume in the pump (Helmholtz resonance and rheoimpedance methods), blood pressure (piezoresistive sensors separated from blood through the polyurethane membrane) and epicardial ECG. Investigations were performed on in-vitro models, which simulated essential biophysical phenomena. Trial measurements were performed on animals (110kg pig). Results: Accuracy of Doppler volumetric blood flow measurement was 20%. For the rheoimpedance method, the difference between measured and reference volume (calculated by flow integration) was 0.44mL with standard deviation=3.5mL (Bland-Altman plot). Helmholtz resonance method allowed to measure blood chamber volume with unreliability of 5%. Accuracy about 3mmHg and negligible hysteresis were obtained for blood pressure measurement gauge. QRS detector efficiency (estimated according to EN-60601-1-2-47 regulation) was > 99%. Conclusions: The performed investigations allowed to select measurement methods appropriate to utilization in final construction of pulsatile VAD. The following methods were chosen: Doppler blood flow, pressure measurement by piezoresistive sensor and QRS detection from epicardial ECG. While developing VAD manufacturing technology the gauges construction limits should be taken into consideration. |
---|---|
AbstractList | Objectives: For optimization, monitoring and partial-automation of mechanical heart support it is necessary to measure appropriate biological signals. The paper presents noninvasive measurement methods of those parameters. Goal of this study was to construct and examine selected biological parameters measurement methods dedicated to pulsatile VAD. This work is a part of the Polish Artificial Heart project. Methods: The following biophysical quantities measurement methods were investigated: blood flow (ultrasound Doppler velocity profile methods), temporary blood volume in the pump (Helmholtz resonance and rheoimpedance methods), blood pressure (piezoresistive sensors separated from blood through the polyurethane membrane) and epicardial ECG. Investigations were performed on in-vitro models, which simulated essential biophysical phenomena. Trial measurements were performed on animals (110kg pig). Results: Accuracy of Doppler volumetric blood flow measurement was 20%. For the rheoimpedance method, the difference between measured and reference volume (calculated by flow integration) was 0.44mL with standard deviation=3.5mL (Bland-Altman plot). Helmholtz resonance method allowed to measure blood chamber volume with unreliability of 5%. Accuracy about 3mmHg and negligible hysteresis were obtained for blood pressure measurement gauge. QRS detector efficiency (estimated according to EN-60601-1-2-47 regulation) was > 99%. Conclusions: The performed investigations allowed to select measurement methods appropriate to utilization in final construction of pulsatile VAD. The following methods were chosen: Doppler blood flow, pressure measurement by piezoresistive sensor and QRS detection from epicardial ECG. While developing VAD manufacturing technology the gauges construction limits should be taken into consideration. |
Author | Lewandowski, M Kapis, A Kustosz, R Gibinski, P Sobotnicki, A Opilski, Z Karlowicz, P Gawlikawski, M Nowicki, A Gorka, K Mocha, J Czerw, M Palko, T Pustelny, T |
Author_xml | – sequence: 1 givenname: M surname: Gawlikawski fullname: Gawlikawski, M – sequence: 2 givenname: R surname: Kustosz fullname: Kustosz, R – sequence: 3 givenname: P surname: Gibinski fullname: Gibinski, P – sequence: 4 givenname: A surname: Nowicki fullname: Nowicki, A – sequence: 5 givenname: T surname: Palko fullname: Palko, T – sequence: 6 givenname: T surname: Pustelny fullname: Pustelny, T – sequence: 7 givenname: K surname: Gorka fullname: Gorka, K – sequence: 8 givenname: A surname: Kapis fullname: Kapis, A – sequence: 9 givenname: J surname: Mocha fullname: Mocha, J – sequence: 10 givenname: A surname: Sobotnicki fullname: Sobotnicki, A – sequence: 11 givenname: M surname: Czerw fullname: Czerw, M – sequence: 12 givenname: Z surname: Opilski fullname: Opilski, Z – sequence: 13 givenname: M surname: Lewandowski fullname: Lewandowski, M – sequence: 14 givenname: P surname: Karlowicz fullname: Karlowicz, P |
BookMark | eNqVysEKgjAYAOAdDNLqHXbsImzNRI9L_nKgm2zLq0gsKEyr5ft36QU6fZcvQsE4jS5AIWE5jVmeZUsUeX8nhKZJsg8Rl0oK2XIjWsAHoSp1EgWvcMM1r8GCNrgGbs4aapAWC4lL4NriRitjSzDCrNHi2g_ebX6u0PYItijj53t6zc5_usfNX9ww9KObZt9RQumOpnlG2B_1C66aOIc |
ContentType | Journal Article |
DBID | 7QO 8FD FR3 P64 |
DatabaseName | Biotechnology Research Abstracts Technology Research Database Engineering Research Database Biotechnology and BioEngineering Abstracts |
DatabaseTitle | Biotechnology Research Abstracts Technology Research Database Engineering Research Database Biotechnology and BioEngineering Abstracts |
DatabaseTitleList | Biotechnology Research Abstracts |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EndPage | 612 |
GroupedDBID | --- 0R~ 36B 3KF 54M 5GY 5RE 5Z9 7QO 8FD 8RF AACMV AAEWN AAKGS AAPEO AARIX AATAA AAWTL ABCCA ABJNI ABLUO ABOCM ABPNF ABRHV ABVFX ACARO ACDXX ACFEJ ACGFO ACGFS ACIWK ACJER ACLFY ACOXC ACPRK ACROE ACSIQ ACUAV ACUIR ACXKE ACXMB ADBBV ADRRZ ADVBO AEGXH AENEX AESZF AEWDL AEWHI AFKRG AFMOU AFQAA AFRAH AFUIA AGKLV AGNHF AIOMO AJUZI AJXAJ ALKWR ALMA_UNASSIGNED_HOLDINGS ALTZF ANDLU ARTOV BBRGL BDDNI BKIIM BKSCU BPACV BSEHC BWJAD DV7 EBS EJD EMOBN F5P FHBDP FR3 GROUPED_SAGE_PREMIER_JOURNAL_COLLECTION H13 HZ~ J8X JCYGO K.F M4V O9- OVD P64 Q1R SAFTQ SCNPE SFC SHG SJN SPQ SPV TEORI ZONMY ZPPRI ZRKOI ZSSAH |
ID | FETCH-proquest_miscellaneous_10112169803 |
ISSN | 0391-3988 |
IngestDate | Fri Oct 25 02:00:21 EDT 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 8 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-proquest_miscellaneous_10112169803 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 content type line 23 ObjectType-Feature-2 |
PQID | 1011216980 |
PQPubID | 23462 |
ParticipantIDs | proquest_miscellaneous_1011216980 |
PublicationCentury | 2000 |
PublicationDate | 20110801 |
PublicationDateYYYYMMDD | 2011-08-01 |
PublicationDate_xml | – month: 08 year: 2011 text: 20110801 day: 01 |
PublicationDecade | 2010 |
PublicationTitle | International journal of artificial organs |
PublicationYear | 2011 |
SSID | ssj0016445 |
Score | 3.8703947 |
Snippet | Objectives: For optimization, monitoring and partial-automation of mechanical heart support it is necessary to measure appropriate biological signals. The... |
SourceID | proquest |
SourceType | Aggregation Database |
StartPage | 612 |
Title | NONINVASIVE BIOLOGICAL PARAMETERS MEASUREMENT IN HEART PROSTHESIS |
URI | https://search.proquest.com/docview/1011216980 |
Volume | 34 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtZ3PS8MwFMeD20G8iD_xNxE8CKPQX_bHsWq2VbdM1jp2G-mawFA6cJaBf71Jl6YdHpwHL6UNJSn9tOnry3vvC8DNNJ1SY8qoRl2aipQcphHCJ8PkzmepbbseMQsR28jFY-8R2agU2uZ__artX0nzNs5aZM7-gbbqlDfwfc6cbzl1vt2IOx7gEI-CKByh1n2otA5egmHQR7FIKOgjPpcOiyr-rRC3uojbtJzEIIq7KAqjurm67i-sVZkQA8vaE4UulLLMO2T5PnsjSymHrfw6zzm3MhdfayGKnVmidLNVmhmeC3H3WeVmTes-VumSkKlYvqFZ_kqvr5xmpc9y9Th5tTnTkXHUdP2oXhkbDybt115vEqNx3AANyxDBm9ETVutF3KorglXLgX98WQtzId4Du9LOh8EK0D7YotkB2O7LSIZDENQ4wYoTrDjBGicYYlhwghWnI3DbRvFDVysvYcJfWbEOQzI6zxciqs4wDcf3dOsYNLN5Rk8A9CzGdJsR0_dc2yR6wpJU95ntECdJbeKcgutfuzvb4JxzsFMhuwDNz4-cXoLGIs2vilv6DSPPJqs |
link.rule.ids | 315,782,786 |
linkProvider | Multiple Vendors |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=NONINVASIVE+BIOLOGICAL+PARAMETERS+MEASUREMENT+IN+HEART+PROSTHESIS&rft.jtitle=International+journal+of+artificial+organs&rft.au=Gawlikawski%2C+M&rft.au=Kustosz%2C+R&rft.au=Gibinski%2C+P&rft.au=Nowicki%2C+A&rft.date=2011-08-01&rft.issn=0391-3988&rft.volume=34&rft.issue=8&rft.spage=612&rft.epage=612&rft.externalDBID=NO_FULL_TEXT |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0391-3988&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0391-3988&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0391-3988&client=summon |