Comparing Volumetric Wear of Lithium Disilicate Against Different Ceramics and Enamel Antagonist An In-Vitro Study
Background: In patients with restored dentitions, it is possible for crowns on opposing teeth to gradually wear each other through chewing and bruxism. Therefore, the wear of restorative materials used for dental crowns is an important mechanical property for their long-term clinical success. Lithiu...
Saved in:
Main Author: | |
---|---|
Format: | Dissertation |
Language: | English |
Published: |
ProQuest Dissertations & Theses
01-01-2023
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Background: In patients with restored dentitions, it is possible for crowns on opposing teeth to gradually wear each other through chewing and bruxism. Therefore, the wear of restorative materials used for dental crowns is an important mechanical property for their long-term clinical success. Lithium disilicate is a widely used dental ceramic due to its strength, machinability, and translucency. Due to the rising use of ceramic restorations, a comparison of the wear resistance of lithium disilicate against different ceramic crown materials is useful for the clinician when selecting a crown material to oppose an existing lithium disilicate crown.Objective: To compare volumetric wear of lithium disilicate against different ceramics (3 mol% yttria-stabilized tetragonal zirconia polycrystals zirconia, 5 mol% yttria-stabilized tetragonal zirconia polycrystals, lithium disilicate glass-ceramic, feldspathic porcelain) and enamel antagonist.Methods: Forty (40) flat lithium disilicate (e.max CAD. Ivoclar Vivadent) specimens (n=8/antagonist material) were prepared by sectioning them into blocks (8mm x 4mm x 4 mm thickness) with a sectioning saw. The specimens were crystallized and mounted in a brass holder with acrylic resin. Specimens were wet polished down to 1200 grit SiC in a polishing wheel. For the antagonist, balls made of 3Y-TZP, 5Y-TZP, LDC, and FP were milled at an external laboratory. The ceramic materials, 3Y-TZP, 5Y-TZP, and e.max were polished with ASAP Indirect+ for 20 seconds each. Similarly, porcelain antagonists were polished with Dialite Feather Lite for 20 seconds each. The enamel cusps were sectioned from extracted human teeth, cleaned with pumice, and mounted into a steel hex screw with acrylic resin to be used as the enamel antagonist. A two-body wear test was performed using a ball-on-disc sliding wear device (UAB custom wear device, Birmingham AL) A 1.5 mm repeating impact/slide wear was conducted in 33% glycerin at 24 °C for 400,000 cycles with a frequency of 1 Hz. The applied load was 15N. Wear resistance was analyzed in a 3D optical non-contact profilometer (VR-5000) measuring volume loss on lithium disilicate specimens. Area loss of the antagonist specimens was analyzed by a digital microscope (VHX Keyence). In addition, Vickers hardness was measured, and surface morphologies were observed after the wear test using a scanning electron microscope. Statistical analysis was performed using 1- way ANOVA, and multiple pair-wise comparisons of means were performed using Tukey’s Post-hoc test. (p<0.05).Results: A one-way ANOVA comparing wear loss values of lithium disilicate as opposed by different ceramics and enamel antagonists showed a significant difference (p < 0.001) in lithium disilicate volume loss values. A one-way ANOVA comparing area loss values of different antagonist specimens as opposed to lithium disilicate, showed a significant difference (p < 0.001) in antagonist area loss values. A one-way ANOVA comparing the hardness of different antagonist specimens showed a significant difference (p < 0.001) in their hardness values.Conclusion: 3Y-TZP caused significantly more wear of lithium disilicate than all other materials. Lithium disilicate and enamel caused significantly lesser wear than zirconia but more wear than feldspathic porcelain on lithium disilicate. Feldspathic porcelain caused the least amount of wear of lithium disilicate. Therefore, clinicians should consider the wear potential of selecting zirconia as a restorative material opposing a lithium disilicate restoration. |
---|---|
ISBN: | 9798379505455 |