Transfer and test of a 1 MV LTD generator at CEA

Summary form only given. The 1 MV Linear Transformer Driver (LTD) generator has been transferred from the site Polygône d'Expérimentation de Moronvilliers to the site of Gramat by the CEA. In order to mitigate both the volume and the duration of the moving operation, only the inner stalk and...

Full description

Saved in:
Bibliographic Details
Published in:2013 Abstracts IEEE International Conference on Plasma Science (ICOPS) p. 1
Main Authors: Toury, Martial, Cartier, Frederic, Caron, Michel, Etchessahar, Bertrand
Format: Conference Proceeding
Language:English
Published: IEEE 01-06-2013
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract Summary form only given. The 1 MV Linear Transformer Driver (LTD) generator has been transferred from the site Polygône d'Expérimentation de Moronvilliers to the site of Gramat by the CEA. In order to mitigate both the volume and the duration of the moving operation, only the inner stalk and the ancillary equipment (high voltage dump tanks, trigger generator, vacuum system, command bay, etc.) were disconnected. The 10 cavities remained compressed together in their own support stand. The generator was reassembled in less than two months. All cavities were opened to check visually that the inner components did not move inside and to carry out some preventive maintenance operations (rebuilding liquid resistors, inspecting insulators, etc.). The generator is now being operated with the same performance as before the transfer. Also, for the first time on this generator, several radiographic shots have been fired with a conical Self Magnetic Pinch (SMP) diode.
AbstractList Summary form only given. The 1 MV Linear Transformer Driver (LTD) generator has been transferred from the site Polygône d'Expérimentation de Moronvilliers to the site of Gramat by the CEA. In order to mitigate both the volume and the duration of the moving operation, only the inner stalk and the ancillary equipment (high voltage dump tanks, trigger generator, vacuum system, command bay, etc.) were disconnected. The 10 cavities remained compressed together in their own support stand. The generator was reassembled in less than two months. All cavities were opened to check visually that the inner components did not move inside and to carry out some preventive maintenance operations (rebuilding liquid resistors, inspecting insulators, etc.). The generator is now being operated with the same performance as before the transfer. Also, for the first time on this generator, several radiographic shots have been fired with a conical Self Magnetic Pinch (SMP) diode.
Author Toury, Martial
Cartier, Frederic
Caron, Michel
Etchessahar, Bertrand
Author_xml – sequence: 1
  givenname: Martial
  surname: Toury
  fullname: Toury, Martial
  organization: DAM, CEA, Gramat, France
– sequence: 2
  givenname: Frederic
  surname: Cartier
  fullname: Cartier, Frederic
  organization: DAM, CEA, Gramat, France
– sequence: 3
  givenname: Michel
  surname: Caron
  fullname: Caron, Michel
  organization: DAM, CEA, Gramat, France
– sequence: 4
  givenname: Bertrand
  surname: Etchessahar
  fullname: Etchessahar, Bertrand
  organization: DAM, CEA, Le Barp, France
BookMark eNp9jrFOwzAQQI-qSCSFL-hyP5BwZ6d2PUZpqw6JhETEGlnqBRWBU9lZ-HsYMnd6w3vDy2EdpiAAW6aSmdzrW1u_d3WpiHVpjNaV4wfIuTJW79iyXUGmdtYUVtF-DRlZTYVTVfUEeUpfREo7ZzKgPvqQRonowwVnSTNOI3pk7D6w7Q_4KUGin6f_YMbmWD_D4-i_k7ws3MD2dOybc3EVkeEWrz8-_g7Lkb5v_wBtoDX8
ContentType Conference Proceeding
DBID 6IE
6IH
CBEJK
RIE
RIO
DOI 10.1109/PLASMA.2013.6633491
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan (POP) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library Online
IEEE Proceedings Order Plans (POP) 1998-present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library Online
  url: http://ieeexplore.ieee.org/Xplore/DynWel.jsp
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Applied Sciences
EISBN 1467351717
9781467351713
EISSN 2576-7208
EndPage 1
ExternalDocumentID 6633491
Genre teaser-abstract
GroupedDBID 29I
29O
6IE
6IF
6IH
6IK
6IL
6IM
6IN
AAJGR
ABLEC
ADZIZ
AI.
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
CHZPO
IEGSK
IJVOP
IPLJI
JC5
M43
OCL
RIE
RIL
RIO
RNS
VH1
ID FETCH-ieee_primary_66334913
IEDL.DBID RIE
ISSN 0730-9244
IngestDate Wed Jun 26 19:25:06 EDT 2024
IsPeerReviewed false
IsScholarly true
Language English
LinkModel DirectLink
MergedId FETCHMERGED-ieee_primary_66334913
ParticipantIDs ieee_primary_6633491
PublicationCentury 2000
PublicationDate 2013-June
PublicationDateYYYYMMDD 2013-06-01
PublicationDate_xml – month: 06
  year: 2013
  text: 2013-June
PublicationDecade 2010
PublicationTitle 2013 Abstracts IEEE International Conference on Plasma Science (ICOPS)
PublicationTitleAbbrev PLASMA
PublicationYear 2013
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0023996
Score 3.7735069
Snippet Summary form only given. The 1 MV Linear Transformer Driver (LTD) generator has been transferred from the site Polygône d'Expérimentation de Moronvilliers to...
SourceID ieee
SourceType Publisher
StartPage 1
SubjectTerms Cavity resonators
Dielectric liquids
Generators
Magnetic liquids
Power transformer insulation
Preventive maintenance
Vacuum systems
Title Transfer and test of a 1 MV LTD generator at CEA
URI https://ieeexplore.ieee.org/document/6633491
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1BT8MgFH5xO3mauhl1at7Bo2ztINIem63LDptZssV4W2gBb61x7f_fgzY1Jrt4IyTAywvwfQ_4HgAvRti3OCfmpkRmmMitZQQKGdNCqhlRaC2EUyOvdvL9M1qkLk3Oa6eFMcb4x2dm4or-Ll-Xee2OyqaEjlw4qXpPxlGj1eqCKwJafy9JM5ZRTCHaDENhEE-362S3SdwzLj5pu_jzl4qHkuXgf0ZcwehXk4fbDm2u4cIUNzBoSSS2S_Q4hMCjD7VAVWgkIllhaVFhiJsPXO8X-OUTTVOojarCeZqMYLxM9_MVc0YcvpvsE4d2fH4L_aIszB1gbCMprdsucmI35HRuMqE4l5oiZRnqexie6-HhfPUYLmfNlw8sCB-hX_3U5gl6R10_e4-fAD1wgec
link.rule.ids 310,311,782,786,791,792,798,23941,23942,25151,27936,54770
linkProvider IEEE
linkToHtml http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV09T8MwED1BGWAq0CKgfNzASNqkNrgZozZVEElVqRFii5LYYUsqmvx_zk5UhNSFzbJk-3Sy_d7ZfmeAJ8WLVzcn5pbyTFk8LwqLQCGzJBfplCi05FyrkYONWH3OFr5Ok_O818IopczjMzXWRXOXL6u80UdlE0JHxrVU_eSFC2G3aq19eEVQa24mac5aFFXwLseQY7uTdehtIk8_5GLjrpM_v6kYMFn2_2fGOQx_VXm43uPNBRyp8hL6HY3EbpHuBmAb_KEWmJYSiUrWWBWYooPRB4bxAr9MqmkKtjGtce57Qxgt_XgeWNqIZNvmn0i68dkV9MqqVNeAbjETotAbRk78htzOVMZTxoSkWFk48gYGh3q4PVz9CKdBHIVJ-LZ6H8HZtP0AwrKdO-jV3426h-OdbB6M938AQviFMg
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=proceeding&rft.title=2013+Abstracts+IEEE+International+Conference+on+Plasma+Science+%28ICOPS%29&rft.atitle=Transfer+and+test+of+a+1+MV+LTD+generator+at+CEA&rft.au=Toury%2C+Martial&rft.au=Cartier%2C+Frederic&rft.au=Caron%2C+Michel&rft.au=Etchessahar%2C+Bertrand&rft.date=2013-06-01&rft.pub=IEEE&rft.issn=0730-9244&rft.eissn=2576-7208&rft.spage=1&rft.epage=1&rft_id=info:doi/10.1109%2FPLASMA.2013.6633491&rft.externalDocID=6633491
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0730-9244&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0730-9244&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0730-9244&client=summon