Visualização de refluxo em aspirador de sangue e reservatório de cardiotomia usados em circulação extracorpórea Flow visualization in blood aspirator and cardiotomy reservoir used in cardiopulmonary bypass
OBJETIVO: Um dos maiores danos causados pela oclusão em bombas de rolete é a hemólise. Estudos comparativos entre bomba de roletes com ajustes não oclusivos e bombas centrífugas têm sido realizados nas últimas décadas na tentativa de desenvolver novos produtos e ajustes que causem menos trauma aos e...
Saved in:
Published in: | Revista brasileira de cirurgia cardiovascular Vol. 24; no. 4; pp. 533 - 539 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
Sociedade Brasileira de Cirurgia Cardiovascular
01-12-2009
|
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract | OBJETIVO: Um dos maiores danos causados pela oclusão em bombas de rolete é a hemólise. Estudos comparativos entre bomba de roletes com ajustes não oclusivos e bombas centrífugas têm sido realizados nas últimas décadas na tentativa de desenvolver novos produtos e ajustes que causem menos trauma aos elementos figurados do sangue. Comumente as bombas de rolete são ajustadas pelo método estático devido à preocupação com fluxos variáveis que podem ocorrer com ajustes não oclusivos. Folga excessiva nos roletes permite refluxo e pode acarretar erros no cálculo dos fluxos pela rotação da bomba, de acordo com os dispositivos adicionados ao circuito e a resistência sistêmica do paciente. O objetivo desse trabalho é avaliar o refluxo causado por dois modelos de bombas de rolete em aspirador de sangue e em reservatório de cardiotomia. MÉTODOS: A visualização do refluxo foi realizada em aspirador de sangue e, em reservatório de cardiotomia, a visualização foi acompanhada de respectiva medida. Foram testados dois modelos de bombas de rolete de diferentes fabricantes, ajustadas pelo método de velocidade de queda e calibração dinâmica. Os testes foram conduzidos com tubos de silicone de 3/8 x 1/16 e 1/2 x 3/32 polegadas de diâmetro em água e solução análoga ao sangue. RESULTADOS: Foram registrados visualmente os refluxos em aspirador de sangue e em reservatório de cardiotomia, com respectiva medida dos valores. As bombas apresentaram diferenças nos refluxos medidos ajustadas pelo método de calibração dinâmica. A bomba #2 apresentou refluxo, ajustada totalmente ocluída. CONCLUSÃO: Os refluxos medidos nos dois modelos de bomba apresentaram diferenças (P<0,008). Os resultados indicam diferenças nas características construtivas ocasionadas pelo processo de fabricação, projeto ou possíveis desgastes. Ajustes pouco oclusivos podem proporcionar variações nos fluxos com a resistência adicionada ao circuito, com dificuldade de correção do fluxo pelo incremento da rotação.OBJECTIVE: One of the major damage caused by occlusion in roller pumps is hemolysis. Comparative studies between roller pump with adjustments non occlusive and centrifugal pumps have been made in recent decades in an attempt to develop new products and adjustments that cause fewer traumas to the figurative elements of blood. Usually the roller pumps are adjusted by the static method due to concern variables flow that can occur with non-occlusive settings. Excessive slack in the rollers provoke back flow and can provides errors in the calculation of flow by the rotation of the pump, according to the devices added to the circuit and the systemic resistance of the patient. The objective of this study is to evaluate the back flow caused by two types of roller pumps in blood aspirator and cardiotomy reservoir. METHOD: Back flow visualization was performed in blood aspirator and cardiotomy reservoir. It was tested two different models of roller pumps, adjusted by drop rate and dynamic calibration. The tests were conducted with silicone tubes of 3/8 x 1/16 e 1/2 x 3/32 inches in diameter in water and solution similar to blood. RESULTS: We recorded back flow visually in blood aspirator and in cardiotomy reservoir with their measure of values. The pumps had differences in refluxes measured adjusted by the dynamic calibration method. Pump#2 presents back flow adjusted fully occluded. CONCLUSION: The back flow measured in two models of pump present differences (P <0.008). The results indicate differences in its characteristics caused by the process of manufacturing, design or possible wear. Non-occlusive adjustments may cause variations in flow with the increase of resistance added to the circuit, with difficulty to fix the flow by increasing the rotation. |
---|---|
AbstractList | OBJETIVO: Um dos maiores danos causados pela oclusão em bombas de rolete é a hemólise. Estudos comparativos entre bomba de roletes com ajustes não oclusivos e bombas centrífugas têm sido realizados nas últimas décadas na tentativa de desenvolver novos produtos e ajustes que causem menos trauma aos elementos figurados do sangue. Comumente as bombas de rolete são ajustadas pelo método estático devido à preocupação com fluxos variáveis que podem ocorrer com ajustes não oclusivos. Folga excessiva nos roletes permite refluxo e pode acarretar erros no cálculo dos fluxos pela rotação da bomba, de acordo com os dispositivos adicionados ao circuito e a resistência sistêmica do paciente. O objetivo desse trabalho é avaliar o refluxo causado por dois modelos de bombas de rolete em aspirador de sangue e em reservatório de cardiotomia. MÉTODOS: A visualização do refluxo foi realizada em aspirador de sangue e, em reservatório de cardiotomia, a visualização foi acompanhada de respectiva medida. Foram testados dois modelos de bombas de rolete de diferentes fabricantes, ajustadas pelo método de velocidade de queda e calibração dinâmica. Os testes foram conduzidos com tubos de silicone de 3/8 x 1/16 e 1/2 x 3/32 polegadas de diâmetro em água e solução análoga ao sangue. RESULTADOS: Foram registrados visualmente os refluxos em aspirador de sangue e em reservatório de cardiotomia, com respectiva medida dos valores. As bombas apresentaram diferenças nos refluxos medidos ajustadas pelo método de calibração dinâmica. A bomba #2 apresentou refluxo, ajustada totalmente ocluída. CONCLUSÃO: Os refluxos medidos nos dois modelos de bomba apresentaram diferenças (P<0,008). Os resultados indicam diferenças nas características construtivas ocasionadas pelo processo de fabricação, projeto ou possíveis desgastes. Ajustes pouco oclusivos podem proporcionar variações nos fluxos com a resistência adicionada ao circuito, com dificuldade de correção do fluxo pelo incremento da rotação.OBJECTIVE: One of the major damage caused by occlusion in roller pumps is hemolysis. Comparative studies between roller pump with adjustments non occlusive and centrifugal pumps have been made in recent decades in an attempt to develop new products and adjustments that cause fewer traumas to the figurative elements of blood. Usually the roller pumps are adjusted by the static method due to concern variables flow that can occur with non-occlusive settings. Excessive slack in the rollers provoke back flow and can provides errors in the calculation of flow by the rotation of the pump, according to the devices added to the circuit and the systemic resistance of the patient. The objective of this study is to evaluate the back flow caused by two types of roller pumps in blood aspirator and cardiotomy reservoir. METHOD: Back flow visualization was performed in blood aspirator and cardiotomy reservoir. It was tested two different models of roller pumps, adjusted by drop rate and dynamic calibration. The tests were conducted with silicone tubes of 3/8 x 1/16 e 1/2 x 3/32 inches in diameter in water and solution similar to blood. RESULTS: We recorded back flow visually in blood aspirator and in cardiotomy reservoir with their measure of values. The pumps had differences in refluxes measured adjusted by the dynamic calibration method. Pump#2 presents back flow adjusted fully occluded. CONCLUSION: The back flow measured in two models of pump present differences (P <0.008). The results indicate differences in its characteristics caused by the process of manufacturing, design or possible wear. Non-occlusive adjustments may cause variations in flow with the increase of resistance added to the circuit, with difficulty to fix the flow by increasing the rotation. |
Author | Lindemberg da Mota Silveira Filho Elaine Soraya Barbosa de Oliveira Severino Orlando Petrucci Junior Eduardo Tavares Costa Francisco Ubaldo Vieira Junior Pedro Paulo Martins de Oliveira Karlos Alexandre de Sousa Vilarinho Nilson Antunes Reinaldo Wilson Vieira |
Author_xml | – sequence: 1 fullname: Francisco Ubaldo Vieira Junior – sequence: 2 fullname: Reinaldo Wilson Vieira – sequence: 3 fullname: Eduardo Tavares Costa – sequence: 4 fullname: Nilson Antunes – sequence: 5 fullname: Orlando Petrucci Junior – sequence: 6 fullname: Pedro Paulo Martins de Oliveira – sequence: 7 fullname: Lindemberg da Mota Silveira Filho – sequence: 8 fullname: Karlos Alexandre de Sousa Vilarinho – sequence: 9 fullname: Elaine Soraya Barbosa de Oliveira Severino |
BookMark | eNqtjU1OwzAQRi1UJFrgDPgCBbv5a9aICtYgttHEdipXjicaJ6XlOiw4AEfoEbgQSQlwARajkWbe970Zm3j0hrErKa5lkoubRyHFYp6l0XIhRC6ESPqRyQmbyjRbzvMslhM2_YXO2CyEjRCLLFqKKft8tqEDZ1_h8H54Q64NJ1O5bofc1BxCYwk00nAP4Ned4QMQDG2hPXyQPSYUkLbYYm2Bd6HnwxBWllTnxl6zawkUUtOHDPCVwxe-_VG3Fj23npcOUY_StpeC13_d-9GLlnqJ0UPg-9l0rkYPtOflvoEQLthpBS6Yy3Gfs4fV3dPt_VwjbIqGbN2zBYItjgekdQHUWuVMYSqh0kpJGedpbKKqjJIylRCXkZaqTJPoP7u-AOBlmkQ |
ContentType | Journal Article |
DBID | DOA |
DOI | 10.1590/S0102-76382009000500015 |
DatabaseName | DOAJ: Directory of Open Access Journals |
DatabaseTitleList | |
Database_xml | – sequence: 1 dbid: DOA name: Directory of Open Access Journals url: http://www.doaj.org/ sourceTypes: Open Website |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1678-9741 |
EndPage | 539 |
ExternalDocumentID | oai_doaj_org_article_ef0c6fc114964e3fb35b61a4b3d1cb65 |
GroupedDBID | 123 29P 2WC 53G 5GY 5VS ABXHO ACIHN ADBBV AEAQA AENEX AHMBA ALIPV ALMA_UNASSIGNED_HOLDINGS APOWU AZFZN BAWUL BCNDV C1A CS3 DIK DU5 E3Z EBS EJD GROUPED_DOAJ GX1 IPNFZ KQ8 OK1 PGMZT RIG RNS RPM RSC SCD TR2 XSB |
ID | FETCH-doaj_primary_oai_doaj_org_article_ef0c6fc114964e3fb35b61a4b3d1cb653 |
IEDL.DBID | DOA |
ISSN | 0102-7638 |
IngestDate | Tue Oct 22 14:44:23 EDT 2024 |
IsDoiOpenAccess | true |
IsOpenAccess | true |
IsPeerReviewed | false |
IsScholarly | true |
Issue | 4 |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-doaj_primary_oai_doaj_org_article_ef0c6fc114964e3fb35b61a4b3d1cb653 |
OpenAccessLink | https://doaj.org/article/ef0c6fc114964e3fb35b61a4b3d1cb65 |
ParticipantIDs | doaj_primary_oai_doaj_org_article_ef0c6fc114964e3fb35b61a4b3d1cb65 |
PublicationCentury | 2000 |
PublicationDate | 2009-12-01 |
PublicationDateYYYYMMDD | 2009-12-01 |
PublicationDate_xml | – month: 12 year: 2009 text: 2009-12-01 day: 01 |
PublicationDecade | 2000 |
PublicationTitle | Revista brasileira de cirurgia cardiovascular |
PublicationYear | 2009 |
Publisher | Sociedade Brasileira de Cirurgia Cardiovascular |
Publisher_xml | – name: Sociedade Brasileira de Cirurgia Cardiovascular |
SSID | ssj0027380 |
Score | 3.60191 |
Snippet | OBJETIVO: Um dos maiores danos causados pela oclusão em bombas de rolete é a hemólise. Estudos comparativos entre bomba de roletes com ajustes não oclusivos e... |
SourceID | doaj |
SourceType | Open Website |
StartPage | 533 |
SubjectTerms | Bombas Circulação extracorpórea Extracorporeal circulation Pumps |
Title | Visualização de refluxo em aspirador de sangue e reservatório de cardiotomia usados em circulação extracorpórea Flow visualization in blood aspirator and cardiotomy reservoir used in cardiopulmonary bypass |
URI | https://doaj.org/article/ef0c6fc114964e3fb35b61a4b3d1cb65 |
Volume | 24 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV29TsMwELagA2JB_IrfygNr1KRpU3vkp1UrBEsRYosc25EitUmUNEB5HQYegEfoI_BC3NlpERMDrLbvLvJd7Dvf-TMh50wKwQXvQpDj9hxEmHMEhLYO7DTKZdDBzfXo4bh398iu-wiTs3rqC2vCLDywnbiWjl0ZxBLcdh50tB9HfjcKPNGJfOXJKLDopW6wDKaWoZZv3kxDwDQH_iBWV3Z1udsarxoxMWAAUNBx-IHZbzaXwTbZqr1CemG_Zoes6XSXbNzWee898vmQlHj78VUs3hdvGVWaws42qV4yqqdUmGy5ygpsL_EAUlMcYA9cFx9FYiikKT2dZdNE0KqE8SUSy6TAUlTLF1bqApbIIgciLehgkj3Tp6VoVCFNUmpq3WuhELFTkapv3vNabpYUIEQrJLCdeTUBkxfFnEbzHFz2fTIa9O-vhg5OSJhb1IsQcahNA2gnrLUT_qYd_4A00izVh4SCJ8Tb2hMwnHcCyTgTMWsLFseeFMpjR-Ty7_KO_4PJCdls169EuN4pacyKSp-R9VJVTbCy0U3T2NoXtG7mfg |
link.rule.ids | 315,782,786,866,2106,27933,27934 |
linkProvider | Directory of Open Access Journals |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Visualiza%C3%A7%C3%A3o+de+refluxo+em+aspirador+de+sangue+e+reservat%C3%B3rio+de+cardiotomia+usados+em+circula%C3%A7%C3%A3o+extracorp%C3%B3rea+Flow+visualization+in+blood+aspirator+and+cardiotomy+reservoir+used+in+cardiopulmonary+bypass&rft.jtitle=Revista+brasileira+de+cirurgia+cardiovascular&rft.au=Francisco+Ubaldo+Vieira+Junior&rft.au=Reinaldo+Wilson+Vieira&rft.au=Eduardo+Tavares+Costa&rft.au=Nilson+Antunes&rft.date=2009-12-01&rft.pub=Sociedade+Brasileira+de+Cirurgia+Cardiovascular&rft.issn=0102-7638&rft.eissn=1678-9741&rft.volume=24&rft.issue=4&rft.spage=533&rft.epage=539&rft_id=info:doi/10.1590%2FS0102-76382009000500015&rft.externalDBID=DOA&rft.externalDocID=oai_doaj_org_article_ef0c6fc114964e3fb35b61a4b3d1cb65 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0102-7638&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0102-7638&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0102-7638&client=summon |