DEVELOPMENT AND VALIDATION OF A HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC METHOD DETERMINATION OF ZIDOVUDINE ENCAPSULATED IN PCL NANOPARTICLES

A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of encapsulation efficiency of zidovudine in nanoparticules. The method was carried out in isocratic mode using 0.040M sodium acetate: methanol: acetonitrile: glacial acetic acid...

Full description

Saved in:
Bibliographic Details
Published in:Drug Analytical Research Vol. 1; no. 2; pp. 1 - 8
Main Authors: Milena Cristina Ribeiro Souza Magalhães, Alisson Samuel Portes Caldeira, Hanna de Sousa Rocha Almeida, Sílvia Ligório Fialho, Armando da Silva Cunha Junior
Format: Journal Article
Language:English
Published: Universidade Federal do Rio Grande do Sul 01-12-2017
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A reversed-phase high-performance liquid chromatographic (HPLC) method was developed and validated for the determination of encapsulation efficiency of zidovudine in nanoparticules. The method was carried out in isocratic mode using 0.040M sodium acetate: methanol: acetonitrile: glacial acetic acid (880:100:20:2) as mobile phase, a C8 column at 25ºC and UV detection at 240 nm. The method was linear (r2 ˃ 0.99) over the range of 25.0-150.0 μg/mL, precise (RSD ˂ 5%), accurate (recovery = 100.5%), robust and selective. The validated HPLC-UV method can be successfully applied to determine the rate of zidovudine in nanoparticules.