Fluxometria da artéria torácica interna esquerda na revascularização da artéria descendente anterior com e sem circulação extracorpórea Flowmetry of left internal thoracic artery graft to left anterior descending artery: comparison between on-pump and off-pump surgery

INTRODUÇÃO: A cirurgia de revascularização do miocárdio (RM) sem circulação extracorpórea (CEC) é uma técnica amplamente utilizada. A fluxometria coronariana é a técnica mais usada para avaliação dos enxertos, porém, poucos estudos comparam os dados fluxométricos na RM com e sem CEC. O objetivo dest...

Full description

Saved in:
Bibliographic Details
Published in:Revista brasileira de cirurgia cardiovascular Vol. 27; no. 2; pp. 283 - 289
Main Authors: Filinto Marques de Cerqueira Neto, Marco Antonio Vieira Guedes, Leonardo Eugênio Fonseca Soares, Gustavo Santiago Almeida, André Raimundo F. Guimarães, Mauricio Alves Barreto, Emerson Costa Porto, Álvaro Rabelo Júnior
Format: Journal Article
Language:English
Published: Sociedade Brasileira de Cirurgia Cardiovascular 01-06-2012
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract INTRODUÇÃO: A cirurgia de revascularização do miocárdio (RM) sem circulação extracorpórea (CEC) é uma técnica amplamente utilizada. A fluxometria coronariana é a técnica mais usada para avaliação dos enxertos, porém, poucos estudos comparam os dados fluxométricos na RM com e sem CEC. O objetivo deste estudo foi comparar as variáveis fluxométricas dos enxertos de artéria torácica interna esquerda para a artéria descendente anterior em pacientes submetidos à RM com e sem CEC. MÉTODOS: Entre março e setembro de 2010, foram analisados retrospectivamente 35 pacientes consecutivos, não randomizados, submetidos à RM. Foram alocados 10 pacientes no grupo A (com CEC) e 25 no grupo B (sem CEC). O fluxo médio do enxerto (FME), o índice pulsátil (PI) e a porcentagem de enchimento diastólico (ED) foram obtidos por meio da fluxometria por tempo de trânsito. Foi utilizado o teste exato de Fisher e Mann-Whitney, sendo considerado estatisticamente significante P<0,05. RESULTADOS: Não houve óbito, infarto agudo do miocárdio ou necessidade de angioplastia em 30 dias de pós-operatório. O número médio de anastomoses distais foi 2,3 ± 0,8 por paciente no grupo sem CEC, e de 2,2 ± 0,6 no grupo com CEC (P=0,10). A mediana do fluxo médio do enxerto foi 23 ml/min, no grupo A, e 25 ml/min, no grupo B (P=0,34). A percentagem de enchimento diastólico foi 56%, no grupo A, e 59,5%, no grupo B (P=0,86). O índice pulsátil foi 2,3, no grupo A, e 2,2, no grupo B (P=0,82). CONCLUSÃO: Não houve diferença nos parâmetros fluxométricos (FME, ED e PI) encontrados nos pacientes submetidos à revascularização do miocárdio com e sem CEC.BACKGROUND: Off-pump coronary bypass grafting (OPCAB) has become a widely used technique. Coronary flowmetry is the most common method employed to assess graft patency, nevertheless, few studies compare flow patterns between ONCAB and OPCAB surgery. The objective of this study was to compare flowmetry data in left internal mammary artery grafts bypasses to the left anterior descendent artery. METHODS: From March to September of 2010, thirtyfive consecutive, non-randomized patients underwent CABG and were retrospectively evaluated. Ten patients were located on group A (On Pump), and twenty-five on group B (Off Pump). The mean graft flow (MGF), pulsatile index (PI) and diastolic filling (DF) were obtained using Transit Time Flowmetry (TTFM). The Fisher exact test, and Mann Whitney test were used, and a P value of < 0.05 was considered to indicate statistical significance. RESULTS: There were no deaths, AMI, re-interventions or PTCA in a 30-day period. The number of bypasses performed per patient was 2.3 ± 0.8 in the OPCAB group, and 2.2 ± 0.6 in the ONCAB group, with no significant difference (P=0.10). The median of mean flow was 23 ml/min on group A, and 25 ml/min on group B (P=0.34). Diastolic filling percentage was 56% on group A, and 56.9% on group B (P=0.86). Pulsatile Index was 2.3 on group A, and 2.2 on group B (P=0.82). CONCLUSIONS: There was no difference between TTFM values (MF, PI and DF) in patients operated with or without cardiopulmonary bypass.
AbstractList INTRODUÇÃO: A cirurgia de revascularização do miocárdio (RM) sem circulação extracorpórea (CEC) é uma técnica amplamente utilizada. A fluxometria coronariana é a técnica mais usada para avaliação dos enxertos, porém, poucos estudos comparam os dados fluxométricos na RM com e sem CEC. O objetivo deste estudo foi comparar as variáveis fluxométricas dos enxertos de artéria torácica interna esquerda para a artéria descendente anterior em pacientes submetidos à RM com e sem CEC. MÉTODOS: Entre março e setembro de 2010, foram analisados retrospectivamente 35 pacientes consecutivos, não randomizados, submetidos à RM. Foram alocados 10 pacientes no grupo A (com CEC) e 25 no grupo B (sem CEC). O fluxo médio do enxerto (FME), o índice pulsátil (PI) e a porcentagem de enchimento diastólico (ED) foram obtidos por meio da fluxometria por tempo de trânsito. Foi utilizado o teste exato de Fisher e Mann-Whitney, sendo considerado estatisticamente significante P<0,05. RESULTADOS: Não houve óbito, infarto agudo do miocárdio ou necessidade de angioplastia em 30 dias de pós-operatório. O número médio de anastomoses distais foi 2,3 ± 0,8 por paciente no grupo sem CEC, e de 2,2 ± 0,6 no grupo com CEC (P=0,10). A mediana do fluxo médio do enxerto foi 23 ml/min, no grupo A, e 25 ml/min, no grupo B (P=0,34). A percentagem de enchimento diastólico foi 56%, no grupo A, e 59,5%, no grupo B (P=0,86). O índice pulsátil foi 2,3, no grupo A, e 2,2, no grupo B (P=0,82). CONCLUSÃO: Não houve diferença nos parâmetros fluxométricos (FME, ED e PI) encontrados nos pacientes submetidos à revascularização do miocárdio com e sem CEC.BACKGROUND: Off-pump coronary bypass grafting (OPCAB) has become a widely used technique. Coronary flowmetry is the most common method employed to assess graft patency, nevertheless, few studies compare flow patterns between ONCAB and OPCAB surgery. The objective of this study was to compare flowmetry data in left internal mammary artery grafts bypasses to the left anterior descendent artery. METHODS: From March to September of 2010, thirtyfive consecutive, non-randomized patients underwent CABG and were retrospectively evaluated. Ten patients were located on group A (On Pump), and twenty-five on group B (Off Pump). The mean graft flow (MGF), pulsatile index (PI) and diastolic filling (DF) were obtained using Transit Time Flowmetry (TTFM). The Fisher exact test, and Mann Whitney test were used, and a P value of < 0.05 was considered to indicate statistical significance. RESULTS: There were no deaths, AMI, re-interventions or PTCA in a 30-day period. The number of bypasses performed per patient was 2.3 ± 0.8 in the OPCAB group, and 2.2 ± 0.6 in the ONCAB group, with no significant difference (P=0.10). The median of mean flow was 23 ml/min on group A, and 25 ml/min on group B (P=0.34). Diastolic filling percentage was 56% on group A, and 56.9% on group B (P=0.86). Pulsatile Index was 2.3 on group A, and 2.2 on group B (P=0.82). CONCLUSIONS: There was no difference between TTFM values (MF, PI and DF) in patients operated with or without cardiopulmonary bypass.
Author André Raimundo F. Guimarães
Marco Antonio Vieira Guedes
Emerson Costa Porto
Filinto Marques de Cerqueira Neto
Gustavo Santiago Almeida
Mauricio Alves Barreto
Leonardo Eugênio Fonseca Soares
Álvaro Rabelo Júnior
Author_xml – sequence: 1
  fullname: Filinto Marques de Cerqueira Neto
– sequence: 2
  fullname: Marco Antonio Vieira Guedes
– sequence: 3
  fullname: Leonardo Eugênio Fonseca Soares
– sequence: 4
  fullname: Gustavo Santiago Almeida
– sequence: 5
  fullname: André Raimundo F. Guimarães
– sequence: 6
  fullname: Mauricio Alves Barreto
– sequence: 7
  fullname: Emerson Costa Porto
– sequence: 8
  fullname: Álvaro Rabelo Júnior
BookMark eNqtjrtOwzAUhgMqEi2wMTH5BVKcpLmxIirY2aNT56S4Suxw7NCWt0EMiJlHyIvh0FKJnelc_H_-zsQbKa3Q864CPo3zKL4OkjTz83QWTEMehJzP4mNvfFiOvDEPeOinSZSdehNjVpyHaZTx8dHlvO42ukFLElgJDMj2n0NvNfVvQgpgUlkkBQzNc4fkMq4nfAEjuhpIvkL_0b_rP3CJRqAq0ZEMBlxqYkI3DJnBhglJA7vjcGMJhKa2_yIENq_1ejhny3TFaqzsr79m9km7pBSDB11gSeCerd7FDp69XKrlPngzqFt3qtGKLdCuERXTym-7pnVY6UzVbjAdLR1w7p1UUBu82Ncz72F-93h775caVkVLsgHaFhpk8bPQtCycSYoaizDKBKSQ5MAXszyIchHNKrFYlEmcJJjH0X_-9Q3kWrEF
ContentType Journal Article
DBID DOA
DOI 10.5935/1678-9741.20120045
DatabaseName DOAJ Directory of Open Access Journals
DatabaseTitleList
Database_xml – sequence: 1
  dbid: DOA
  name: Directory of Open Access Journals
  url: http://www.doaj.org/
  sourceTypes: Open Website
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1678-9741
EndPage 289
ExternalDocumentID oai_doaj_org_article_238ca7a69a0b49139c34fcbbd6566e95
GroupedDBID 123
29P
2WC
53G
5GY
5VS
7RV
7X7
88E
8C1
8FI
8FJ
8G5
ABDHV
ABUWG
ABXHO
ACIHN
ADBBV
AEAQA
AENEX
AFKRA
AHMBA
ALIPV
ALMA_UNASSIGNED_HOLDINGS
APOWU
AZFZN
AZQEC
BAWUL
BCNDV
BENPR
CCPQU
CS3
DIK
DU5
DWQXO
E3Z
EBD
EBS
EJD
EMOBN
FYUFA
GNUQQ
GROUPED_DOAJ
GUQSH
GX1
HMCUK
IPNFZ
KQ8
M1P
M2O
NAPCQ
OK1
PADUT
PGMZT
PIMPY
PSQYO
RIG
RNS
RPM
RSC
SCD
SV3
TR2
UKHRP
XSB
ID FETCH-doaj_primary_oai_doaj_org_article_238ca7a69a0b49139c34fcbbd6566e953
IEDL.DBID DOA
ISSN 0102-7638
IngestDate Tue Oct 22 15:16:09 EDT 2024
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed false
IsScholarly true
Issue 2
Language English
LinkModel DirectLink
MergedId FETCHMERGED-doaj_primary_oai_doaj_org_article_238ca7a69a0b49139c34fcbbd6566e953
OpenAccessLink https://doaj.org/article/238ca7a69a0b49139c34fcbbd6566e95
ParticipantIDs doaj_primary_oai_doaj_org_article_238ca7a69a0b49139c34fcbbd6566e95
PublicationCentury 2000
PublicationDate 2012-06-01
PublicationDateYYYYMMDD 2012-06-01
PublicationDate_xml – month: 06
  year: 2012
  text: 2012-06-01
  day: 01
PublicationDecade 2010
PublicationTitle Revista brasileira de cirurgia cardiovascular
PublicationYear 2012
Publisher Sociedade Brasileira de Cirurgia Cardiovascular
Publisher_xml – name: Sociedade Brasileira de Cirurgia Cardiovascular
SSID ssj0027380
Score 3.7879024
Snippet INTRODUÇÃO: A cirurgia de revascularização do miocárdio (RM) sem circulação extracorpórea (CEC) é uma técnica amplamente utilizada. A fluxometria coronariana é...
SourceID doaj
SourceType Open Website
StartPage 283
SubjectTerms Coronary artery bypass
Coronary artery bypass, off-pump
Flowmeters
Fluxometria por laser-doppler
Fluxômetros
Laser-doppler flowmetry
Myocardial revascularization
Ponte de artéria coronária
Ponte de artéria coronária sem circulação extracorpórea
Revascularização miocárdica
Title Fluxometria da artéria torácica interna esquerda na revascularização da artéria descendente anterior com e sem circulação extracorpórea Flowmetry of left internal thoracic artery graft to left anterior descending artery: comparison between on-pump and off-pump surgery
URI https://doaj.org/article/238ca7a69a0b49139c34fcbbd6566e95
Volume 27
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV29TsMwEDbQAbEgoCB-qxtYo6ZJ3CZs_LQqQrDAwBYltgOR2rpKWkF5G8SAmHmEvBh3cVqpEwNsTuLLnc4X-845f8fYqVLcsX0hrYhSqLwg5pafOJ7FbdWRkhDIJW249e87d4_-VZdgchalvignzMADG8U1cUkRUSdqB5Ede4RhKVwvEXEsyRFRgUEvtdvzYGoearllzTQCTLPwC_LNcRkeuLzZwunZQi-agsMW2Qhfgusv15XeFtusHEI4N4Jss1U12mHrt9Uv7_pKvTeYvuohFb6KQEaAEhdf1MZguXgXqGNIza4eqBwn-Qz7YDtT8xzT9C0qPosPvUQsSxQnOqSroNRtqjNA4wMFuRqCSDOiNXQ4fWc4b2bj4hs9TOgN9AuJMwOdwEAlkzn_AUye0aBQJCgTRWfwlEX4eKJNtwWfijkumlXHMxCLcohQZY6BHlljtDUkk8gpMRe5OcW9y6573YfLvkUaDccGMSMkDOvyBo5sWI1s-NvIunusNtIjtc-g7Trc8VWA4ZfvqU4Se8qTPEBfxQkET1oH7OLv_A7_4yVHbIPMyiSTHbPaJJuqE7aWy2kDLfT6plHa6Q__YPxn
link.rule.ids 315,782,786,866,2106,27933,27934
linkProvider Directory of Open Access Journals
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Fluxometria+da+art%C3%A9ria+tor%C3%A1cica+interna+esquerda+na+revasculariza%C3%A7%C3%A3o+da+art%C3%A9ria+descendente+anterior+com+e+sem+circula%C3%A7%C3%A3o+extracorp%C3%B3rea+Flowmetry+of+left+internal+thoracic+artery+graft+to+left+anterior+descending+artery%3A+comparison+between+on-pump+and+off-pump+surgery&rft.jtitle=Revista+brasileira+de+cirurgia+cardiovascular&rft.au=Filinto+Marques+de+Cerqueira+Neto&rft.au=Marco+Antonio+Vieira+Guedes&rft.au=Leonardo+Eug%C3%AAnio+Fonseca+Soares&rft.au=Gustavo+Santiago+Almeida&rft.date=2012-06-01&rft.pub=Sociedade+Brasileira+de+Cirurgia+Cardiovascular&rft.issn=0102-7638&rft.eissn=1678-9741&rft.volume=27&rft.issue=2&rft.spage=283&rft.epage=289&rft_id=info:doi/10.5935%2F1678-9741.20120045&rft.externalDBID=DOA&rft.externalDocID=oai_doaj_org_article_238ca7a69a0b49139c34fcbbd6566e95
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0102-7638&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0102-7638&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0102-7638&client=summon