Abstract 122: Compression-Induced Ventilation Volumes Decrease with Chest Compression Depth and Prolonged CPR
Abstract only Introduction: Compression-induced ventilation may aid gas exchange during CPR. We hypothesized that the amount of gas moving in and out of the lungs depends on chest compression depth. Methods: VF was induced in five female, anesthetized and intubated pigs of about 30 kg. After 30 seco...
Saved in:
Published in: | Circulation (New York, N.Y.) Vol. 130; no. suppl_2 |
---|---|
Main Authors: | , , , |
Format: | Journal Article |
Language: | English |
Published: |
25-11-2014
|
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Abstract only
Introduction:
Compression-induced ventilation may aid gas exchange during CPR. We hypothesized that the amount of gas moving in and out of the lungs depends on chest compression depth.
Methods:
VF was induced in five female, anesthetized and intubated pigs of about 30 kg. After 30 seconds of non-intervention time, chest compressions were started and maintained at a rate of 100 compressions per minute. Every two minutes chest compression depth was altered, resulting in 14 minutes of CPR with a depth sequence of 4 cm, 3 cm, 4 cm, 5 cm, 5.5 cm, 5 cm and 4 cm. Ventilations were performed manually with a bag-valve device 10 times per minute during continuous chest compressions by a dedicated expert. Airway flow was measured at the end of the endotracheal tube. Compression-induced ventilation was determined from the periods between the manual ventilations. The average compression-induced minute ventilation volume was determined over the last minute of each two minute period of CPR at each specific chest compression depth.
Results:
The compression-induced ventilation volume in the first period of CPR at 4 cm of depth was 1.6 ± 0.9 L/min (about 4% of total ventilation volume). The figure shows how the compression-induced ventilation volume decreases with increasing chest compression depth, relative to this initial value. CPR with a chest compression depth of 4 cm was performed three times in each pig, and the corresponding compression-induced ventilation volumes decreased with time. This suggested that there might be just a time effect (e.g. atelectasis). However, the final compression depth of 4 cm resulted in larger compression-induced ventilation volumes than the preceding 5 cm and 5.5 cm compression depths, indicating that the decreased volume over time could not purely be a time effect, but must also be an effect of the depth.
Conclusion:
In conclusion, compression-induced ventilation volume appears to decrease with deeper chest compressions as well as with prolonged CPR. |
---|---|