Remote Monitoring of Implantable Cardioverter-Defibrillators: A Systematic Review and Meta-Analysis of Clinical Outcomes

Remote monitoring (RM) of implantable cardioverter-defibrillators (ICD) is an established technology integrated into clinical practice. One recent randomized controlled trial (RCT) and several large device database studies have demonstrated a powerful survival advantage for ICD patients undergoing R...

Full description

Saved in:
Bibliographic Details
Published in:Journal of the American College of Cardiology Vol. 65; no. 24; pp. 2591 - 2600
Main Authors: Parthiban, Nirmalatiban, Esterman, Adrian, Mahajan, Rajiv, Twomey, Darragh J, Pathak, Rajeev K, Lau, Dennis H, Roberts-Thomson, Kurt C, Young, Glenn D, Sanders, Prashanthan, Ganesan, Anand N
Format: Journal Article
Language:English
Published: United States 23-06-2015
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract Remote monitoring (RM) of implantable cardioverter-defibrillators (ICD) is an established technology integrated into clinical practice. One recent randomized controlled trial (RCT) and several large device database studies have demonstrated a powerful survival advantage for ICD patients undergoing RM compared with those receiving conventional in-office (IO) follow-up. This study sought to conduct a systematic published data review and meta-analysis of RCTs comparing RM with IO follow-up. Electronic databases and reference lists were searched for RCTs reporting clinical outcomes in ICD patients who did or did not undergo RM. Data were extracted from 9 RCTs, including 6,469 patients, 3,496 of whom were randomized to RM and 2,973 to IO follow-up. In the RCT setting, RM demonstrated clinical outcomes comparable with office follow-up in terms of all-cause mortality (odds ratio [OR]: 0.83; p = 0.285), cardiovascular mortality (OR: 0.66; p = 0.103), and hospitalization (OR: 0.83; p = 0.196). However, a reduction in all-cause mortality was noted in the 3 trials using home monitoring (OR: 0.65; p = 0.021) with daily verification of transmission. Although the odds of receiving any ICD shock were similar in RM and IO patients (OR: 1.05; p = 0.86), the odds of inappropriate shock were reduced in RM patients (OR: 0.55; p = 0.002). Meta-analysis of RCTs demonstrates that RM and IO follow-up showed comparable overall outcomes related to patient safety and survival, with a potential survival benefit in RCTs using daily transmission verification. RM benefits include more rapid clinical event detection and a reduction in inappropriate shocks.
AbstractList Remote monitoring (RM) of implantable cardioverter-defibrillators (ICD) is an established technology integrated into clinical practice. One recent randomized controlled trial (RCT) and several large device database studies have demonstrated a powerful survival advantage for ICD patients undergoing RM compared with those receiving conventional in-office (IO) follow-up. This study sought to conduct a systematic published data review and meta-analysis of RCTs comparing RM with IO follow-up. Electronic databases and reference lists were searched for RCTs reporting clinical outcomes in ICD patients who did or did not undergo RM. Data were extracted from 9 RCTs, including 6,469 patients, 3,496 of whom were randomized to RM and 2,973 to IO follow-up. In the RCT setting, RM demonstrated clinical outcomes comparable with office follow-up in terms of all-cause mortality (odds ratio [OR]: 0.83; p = 0.285), cardiovascular mortality (OR: 0.66; p = 0.103), and hospitalization (OR: 0.83; p = 0.196). However, a reduction in all-cause mortality was noted in the 3 trials using home monitoring (OR: 0.65; p = 0.021) with daily verification of transmission. Although the odds of receiving any ICD shock were similar in RM and IO patients (OR: 1.05; p = 0.86), the odds of inappropriate shock were reduced in RM patients (OR: 0.55; p = 0.002). Meta-analysis of RCTs demonstrates that RM and IO follow-up showed comparable overall outcomes related to patient safety and survival, with a potential survival benefit in RCTs using daily transmission verification. RM benefits include more rapid clinical event detection and a reduction in inappropriate shocks.
Background Remote monitoring (RM) of implantable cardioverter-defibrillators (ICD) is an established technology integrated into clinical practice. One recent randomized controlled trial (RCT) and several large device database studies have demonstrated a powerful survival advantage for ICD patients undergoing RM compared with those receiving conventional in-office (IO) follow-up. Objectives This study sought to conduct a systematic published data review and meta-analysis of RCTs comparing RM with IO follow-up. Methods Electronic databases and reference lists were searched for RCTs reporting clinical outcomes in ICD patients who did or did not undergo RM. Data were extracted from 9 RCTs, including 6,469 patients, 3,496 of whom were randomized to RM and 2,973 to IO follow-up. Results In the RCT setting, RM demonstrated clinical outcomes comparable with office follow-up in terms of all-cause mortality (odds ratio [OR]: 0.83; p = 0.285), cardiovascular mortality (OR: 0.66; p = 0.103), and hospitalization (OR: 0.83; p = 0.196). However, a reduction in all-cause mortality was noted in the 3 trials using home monitoring (OR: 0.65; p = 0.021) with daily verification of transmission. Although the odds of receiving any ICD shock were similar in RM and IO patients (OR: 1.05; p = 0.86), the odds of inappropriate shock were reduced in RM patients (OR: 0.55; p = 0.002). Conclusions Meta-analysis of RCTs demonstrates that RM and IO follow-up showed comparable overall outcomes related to patient safety and survival, with a potential survival benefit in RCTs using daily transmission verification. RM benefits include more rapid clinical event detection and a reduction in inappropriate shocks.
BACKGROUNDRemote monitoring (RM) of implantable cardioverter-defibrillators (ICD) is an established technology integrated into clinical practice. One recent randomized controlled trial (RCT) and several large device database studies have demonstrated a powerful survival advantage for ICD patients undergoing RM compared with those receiving conventional in-office (IO) follow-up.OBJECTIVESThis study sought to conduct a systematic published data review and meta-analysis of RCTs comparing RM with IO follow-up.METHODSElectronic databases and reference lists were searched for RCTs reporting clinical outcomes in ICD patients who did or did not undergo RM. Data were extracted from 9 RCTs, including 6,469 patients, 3,496 of whom were randomized to RM and 2,973 to IO follow-up.RESULTSIn the RCT setting, RM demonstrated clinical outcomes comparable with office follow-up in terms of all-cause mortality (odds ratio [OR]: 0.83; p = 0.285), cardiovascular mortality (OR: 0.66; p = 0.103), and hospitalization (OR: 0.83; p = 0.196). However, a reduction in all-cause mortality was noted in the 3 trials using home monitoring (OR: 0.65; p = 0.021) with daily verification of transmission. Although the odds of receiving any ICD shock were similar in RM and IO patients (OR: 1.05; p = 0.86), the odds of inappropriate shock were reduced in RM patients (OR: 0.55; p = 0.002).CONCLUSIONSMeta-analysis of RCTs demonstrates that RM and IO follow-up showed comparable overall outcomes related to patient safety and survival, with a potential survival benefit in RCTs using daily transmission verification. RM benefits include more rapid clinical event detection and a reduction in inappropriate shocks.
Author Ganesan, Anand N
Esterman, Adrian
Lau, Dennis H
Young, Glenn D
Parthiban, Nirmalatiban
Pathak, Rajeev K
Mahajan, Rajiv
Twomey, Darragh J
Sanders, Prashanthan
Roberts-Thomson, Kurt C
Author_xml – sequence: 1
  givenname: Nirmalatiban
  surname: Parthiban
  fullname: Parthiban, Nirmalatiban
  organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia; Perdana University-Royal College of Surgeons in Ireland, Serdang, Malaysia
– sequence: 2
  givenname: Adrian
  surname: Esterman
  fullname: Esterman, Adrian
  organization: University of South Australia, Adelaide, Australia
– sequence: 3
  givenname: Rajiv
  surname: Mahajan
  fullname: Mahajan, Rajiv
  organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia
– sequence: 4
  givenname: Darragh J
  surname: Twomey
  fullname: Twomey, Darragh J
  organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia
– sequence: 5
  givenname: Rajeev K
  surname: Pathak
  fullname: Pathak, Rajeev K
  organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia
– sequence: 6
  givenname: Dennis H
  surname: Lau
  fullname: Lau, Dennis H
  organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia
– sequence: 7
  givenname: Kurt C
  surname: Roberts-Thomson
  fullname: Roberts-Thomson, Kurt C
  organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia
– sequence: 8
  givenname: Glenn D
  surname: Young
  fullname: Young, Glenn D
  organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia
– sequence: 9
  givenname: Prashanthan
  surname: Sanders
  fullname: Sanders, Prashanthan
  organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia
– sequence: 10
  givenname: Anand N
  surname: Ganesan
  fullname: Ganesan, Anand N
  email: aganesan@gmail.com
  organization: Centre for Heart Rhythm Disorders, South Australian Health and Medical Research Institute, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australia. Electronic address: aganesan@gmail.com
BackLink https://www.ncbi.nlm.nih.gov/pubmed/25983009$$D View this record in MEDLINE/PubMed
BookMark eNqFkL1OwzAYRS0EgvLzAgzII0vCZ8eObbaq_EpUlYC9ctwvyFVil9gt9O0pAmamuxwd6Z5jsh9iQELOGZQMWH21LJfWuZIDkyWIErjZIyMmpS4qadQ-GYGqZMHAqCNynNISAGrNzCE54tLoCsCMyOcz9jEjncbgcxx8eKOxpY_9qrMh26ZDOrHDwscNDhmH4gZb3wy-6-wOTtd0TF-2KWNvs3f0GTceP6gNCzrFbItxsN02-fRtnHQ-eGc7OltnF3tMp-SgtV3Cs989Ia93t6-Th-Jpdv84GT8VKy5ELtCiEFIyxxm0Trc11q7RrQbTKGgbXoMyoLnSrhYKhKpE1SpuBSy04lJVJ-TyR7sa4vsaU573PjncHQgY12nOdkGYqCsw_6O1Ac4UU7BDL37RddPjYr4afG-H7fyva_UFCOZ87Q
ContentType Journal Article
Copyright Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Copyright_xml – notice: Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
DBID CGR
CUY
CVF
ECM
EIF
NPM
7X8
7QO
8FD
FR3
P64
DOI 10.1016/j.jacc.2015.04.029
DatabaseName Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
Biotechnology Research Abstracts
Technology Research Database
Engineering Research Database
Biotechnology and BioEngineering Abstracts
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
Engineering Research Database
Biotechnology Research Abstracts
Technology Research Database
Biotechnology and BioEngineering Abstracts
DatabaseTitleList MEDLINE
Engineering Research Database
MEDLINE - Academic
Database_xml – sequence: 1
  dbid: ECM
  name: MEDLINE
  url: https://search.ebscohost.com/login.aspx?direct=true&db=cmedm&site=ehost-live
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1558-3597
EndPage 2600
ExternalDocumentID 25983009
Genre Meta-Analysis
Journal Article
Review
GroupedDBID ---
--K
--M
.1-
.FO
.~1
0R~
0SF
18M
1B1
1P~
1~.
1~5
2WC
3V.
4.4
457
4G.
53G
5GY
5RE
5VS
6I.
6PF
7-5
71M
7RV
8P~
AABNK
AABVL
AACTN
AAEDT
AAEDW
AAFTH
AAIKJ
AAKUH
AALRI
AAOAW
AAQFI
AAXUO
ABBQC
ABFNM
ABFRF
ABJNI
ABLJU
ABMAC
ABMZM
ABOCM
ABVKL
ACGFO
ACGFS
ACIUM
ACJTP
ACPRK
ADBBV
ADEZE
ADVLN
AEFWE
AEKER
AENEX
AEVXI
AEXQZ
AFCTW
AFETI
AFRAH
AFRHN
AFTJW
AGHFR
AGYEJ
AHMBA
AITUG
AJOXV
AJRQY
AKRWK
ALMA_UNASSIGNED_HOLDINGS
AMFUW
AMRAJ
BAWUL
BENPR
BLXMC
BPHCQ
CGR
CS3
CUY
CVF
DIK
DU5
E3Z
EBS
ECM
EIF
EJD
EO8
EO9
EP2
EP3
F5P
FDB
FEDTE
FNPLU
G-Q
GBLVA
GX1
H13
HVGLF
IHE
IXB
J1W
K-O
KQ8
L7B
MO0
N9A
NCXOZ
NPM
O-L
O9-
OA.
OAUVE
OK1
OL~
OZT
P-8
P-9
P2P
PC.
PQQKQ
PROAC
Q38
RIG
ROL
RPZ
SCC
SDF
SDG
SDP
SES
SSZ
T5K
TR2
UNMZH
UV1
W8F
WH7
WOQ
WOW
YYM
YZZ
Z5R
7X8
7QO
8FD
FR3
P64
ID FETCH-LOGICAL-p244t-eae44551c210fc8f6e6cb8f809b70fb2607908278c647047343f72a40d872573
ISSN 0735-1097
IngestDate Fri Oct 25 07:20:18 EDT 2024
Fri Oct 25 03:56:44 EDT 2024
Tue Oct 15 23:53:50 EDT 2024
IsPeerReviewed true
IsScholarly true
Issue 24
Keywords mortality
home monitoring
sudden cardiac death
shock
Language English
License Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
LinkModel OpenURL
MergedId FETCHMERGED-LOGICAL-p244t-eae44551c210fc8f6e6cb8f809b70fb2607908278c647047343f72a40d872573
Notes ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
ObjectType-Review-4
content type line 23
ObjectType-Undefined-3
ObjectType-Article-1
ObjectType-Feature-2
PMID 25983009
PQID 1690217170
PQPubID 23479
PageCount 10
ParticipantIDs proquest_miscellaneous_1819146309
proquest_miscellaneous_1690217170
pubmed_primary_25983009
PublicationCentury 2000
PublicationDate 2015-06-23
PublicationDateYYYYMMDD 2015-06-23
PublicationDate_xml – month: 06
  year: 2015
  text: 2015-06-23
  day: 23
PublicationDecade 2010
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Journal of the American College of Cardiology
PublicationTitleAlternate J Am Coll Cardiol
PublicationYear 2015
References 26031697 - Nat Rev Cardiol. 2015 Jul;12(7):380
25983010 - J Am Coll Cardiol. 2015 Jun 23;65(24):2611-3
References_xml
SSID ssj0006819
Score 2.603622
SecondaryResourceType review_article
Snippet Remote monitoring (RM) of implantable cardioverter-defibrillators (ICD) is an established technology integrated into clinical practice. One recent randomized...
BACKGROUNDRemote monitoring (RM) of implantable cardioverter-defibrillators (ICD) is an established technology integrated into clinical practice. One recent...
Background Remote monitoring (RM) of implantable cardioverter-defibrillators (ICD) is an established technology integrated into clinical practice. One recent...
SourceID proquest
pubmed
SourceType Aggregation Database
Index Database
StartPage 2591
SubjectTerms Cardiovascular Diseases - diagnosis
Cardiovascular Diseases - epidemiology
Cardiovascular Diseases - therapy
Defibrillators, Implantable - standards
Electric Countershock - methods
Electric Countershock - standards
Humans
Randomized Controlled Trials as Topic - methods
Remote Sensing Technology - methods
Remote Sensing Technology - standards
Treatment Outcome
Title Remote Monitoring of Implantable Cardioverter-Defibrillators: A Systematic Review and Meta-Analysis of Clinical Outcomes
URI https://www.ncbi.nlm.nih.gov/pubmed/25983009
https://search.proquest.com/docview/1690217170
https://search.proquest.com/docview/1819146309
Volume 65
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://sdu.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9swDBbSDhh2GfZe94IG7OrBtmRL3q1IXfTQpkPrAcUuhmRLS3JwCicZ9vNHWnLs7lF0h12MQEgcW_xEUhT5kZAPOlKGVzwNRJJFGLqpA5XAwgPLZbmNbaZq3CieXIrZlTzKeT6Z9E3WhrH_KmkYA1lj5ew_SHt3UxiAzyBzuILU4XonuV8YmPx-rbY-pxk5gGEKuzKpqctANZjLGRwZizn_gAXsuuPK1C8HcmdPu98lY5iNCsYUJtO-pvJ8u4EX8bmIv_u5o9qVZhyncM8xDup_hteZL7QLyc4WYDIwUU8P-M3XnSFxrAd1O0L2mZqrpT_SUsvF911AAhkmXKKAalv1be6PwXycI0owH8uVInt1KBhyprps3l53uz4THqMxH2vixHUB81Ydefj_aDFc8GL5cakqZLSMko751kdhbtBzz87L4y-np2WRXxV75F4Mmg0V69fkYmf6U9l1ktk9qq_ScgmFv_7D3_c0nW9TPCIPvbDooUPTYzIxzRNy_8ynXTwlPxyo6AAqurJ0BCp6C6g-0UM6QIo6SFGAFL0BKbxjDynaQ-oZKY7zYnoS-JYdwTX4iZvAwMrn4IRXcRTaStrUpJWWVoaZFqHVIAWRgdMpZJVyEXLBOLMiVjyspQDjwZ6T_WbVmJeEas1CHulaM53yqubgNjPYy6c1k9xwZg7I-372StCIeMylGrParks8-IWNdiTCW76DcQqesjA7IC_c1JfXjt6lBORIBluPV3f49WvyYMDqG7K_abfmLdlb19t3HTJ-Asozl68
link.rule.ids 315,782,786,27933,27934
linkProvider Elsevier
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Remote+Monitoring+of+Implantable+Cardioverter-Defibrillators%3A+A+Systematic+Review+and+Meta-Analysis+of+Clinical+Outcomes&rft.jtitle=Journal+of+the+American+College+of+Cardiology&rft.au=Parthiban%2C+Nirmalatiban&rft.au=Esterman%2C+Adrian&rft.au=Mahajan%2C+Rajiv&rft.au=Twomey%2C+Darragh+J&rft.date=2015-06-23&rft.issn=0735-1097&rft.volume=65&rft.issue=24&rft.spage=2591&rft.epage=2600&rft_id=info:doi/10.1016%2Fj.jacc.2015.04.029&rft.externalDBID=NO_FULL_TEXT
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0735-1097&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0735-1097&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0735-1097&client=summon