European multi-centre validation study of NucliSens Extractor in combination with HCV Amplicor 2.0 assay for HCV-NAT screening of plasma pools

The NucliSens Extractor in combination with the 2.0 version of the Roche Cobas HCV Amplicor test has been validated by five European blood screening laboratories in a multi-centre study. For testing the performance characteristics of this HCV-NAT method, the European Pharmacopoeia validation guideli...

Full description

Saved in:
Bibliographic Details
Published in:Biologicals Vol. 27; no. 4; pp. 303 - 314
Main Authors: Cuypers, H T, van Dijk, R, Viret, J F, Schottstedt, V, Lankinen, M, Da Silva Cardoso, M, Lelie, P N
Format: Journal Article
Language:English
Published: England 01-12-1999
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The NucliSens Extractor in combination with the 2.0 version of the Roche Cobas HCV Amplicor test has been validated by five European blood screening laboratories in a multi-centre study. For testing the performance characteristics of this HCV-NAT method, the European Pharmacopoeia validation guidelines were followed. The CLB VQC reference reagents were used for testing robustness and sensitivity. After a technical improvement in the extraction stations, the NucliSens Extractor appeared to be contamination-free as was proved by testing negative controls alternating with samples containing a high HCV-RNA concentration. The Pelicheck HCV-RNA genotype 1 dilution panel was tested 74 times in the five laboratories and an overall 95% detection limit of 80 genome equivalents (geq)/ml was found. In one laboratory the Pelicheck panel was tested in 25 runs and here a 95% detection limit of 32 geq/ml was achieved. In this laboratory the Pelispy HCV-RNA run control samples of 140 geq/ml were consistently picked up in all extractor stations. In addition the laboratories have tested a WHO HCV-RNA genotype 1 standard dilution series 39 times and a Pelicheck HCV-RNA genotype 3 reference panel in 32 test runs. The limiting dilution analysis enabled us to compare the detection efficiency of the NucliSens-Amplicor method for the genoype 1 and genotype 3 isolates and to calibrate the reference reagents against each other. The combined Nuclisens-Amplicor method was found to detect the genotype 3 isolate in the Pelicheck HCV-RNA panels with 2-3 fold lower efficiency than the genotype 1 standard (assuming that the historical calibration of the genotype 3 against the genotype 1 standard is correct). In this study of a single method 1 IU of the WHO HCV-RNA standard was found to be equivalent to 5.1 geq of the VQC HCV-RNA standard (95% confidence intervals 3.1-9.1 geq). To avoid confusion with the use of the CLB VQC reagents we accept the NIBSC collaborative study in which calibration by a variety of methods showed that the Pelispy 380 geq/ml run control is equivalent to 100 IU/ml of the WHO standard. This multi-centre validation study demonstrates that the 95% detection limit of the NucliSens HCV Amplicor method lies far below the detection limits required by the international regulatory bodies.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Article-1
ObjectType-Feature-2
ISSN:1045-1056
DOI:10.1006/biol.1999.0225