Determination of haloperidol and hydroxy haloperidol in human plasma by high performance liquid chromatography
A method has been developed for the separation and measurement of haloperidol and hydroxy haloperidol in human plasma through high performance liquid chromatography. The method uses chlorohaloperidol as an internal standard and provides a limit of detection of about 0.7 nmol/l for haloperidol and 0....
Saved in:
Published in: | Annales de biologie clinique (Paris) Vol. 48; no. 7; p. 455 |
---|---|
Main Authors: | , , , , , |
Format: | Journal Article |
Language: | English |
Published: |
France
1990
|
Subjects: | |
Online Access: | Get more information |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A method has been developed for the separation and measurement of haloperidol and hydroxy haloperidol in human plasma through high performance liquid chromatography. The method uses chlorohaloperidol as an internal standard and provides a limit of detection of about 0.7 nmol/l for haloperidol and 0.67 nmol/l for hydroxy haloperidol. HPLC and RIA radioimmunoassay methods are compared. |
---|---|